Rugged LTE serial/Ethernet-to-cellular gateway
The OnCell G3150A-LTE is a reliable, secure, LTE gateway with state-ofthe-art global LTE coverage. This LTE cellular gateway provides a more reliable connection to your serial connection and Ethernet network for cellular applications.
To enhance industrial reliability, the OnCell G3150A-LTE features isolated power inputs, which together with high-level EMS and widetemperature support give the OnCell G3150A-LTE the highest level of device stability for any rugged environment. In addition, with dual-SIM GuaranLink and dual power inputs, the OnCell G3150A-LTE supports network redundancy to ensure uninterrupted connectivity.
The OnCell G3150A-LTE also comes with a 3-in-1 serial port for serial over LTE cellular network communication. Use the OnCell G3150A-LTE to collect data and exchange data with serial devices.
• Multi-band support
• Secure and reliable VPN support with NAT/ OpenVPN / GRE/ IPsec functionality
•Complies with the following cybersecurity standards:
IACS Components: IEC 62443-4-2 Level 1
IACS (Industrial Automation and Control Systems)
• Dual power inputs for power redundancy
• Dual-SIM support for cellular connection redundancy
• Power isolation for power source insulation protection
• 4-tier GuaranLink for reliable cellular connectivity
• -30 to 70°C wide operating temperature support
• Cellular Interface | |
Standards | GSM/GPRS/EDGE/UMTS/HSPA/LTE |
Band Options | EU Band: • B1 (2100 MHz) / B3 (1800 MHz) / B7 (2600 MHz) / B8 (900 MHz) / B20 (800 MHz) • UMTS/HSPA 2100/1900/850/800/900 MHz US Band: • B2 (1900 MHz) / B4 (AWS) / B5 (850 MHz) / B13 (700 MHz) / B17 (700 MHz) / B25 (1900 MHz) • UMTS/HSPA 2100/1900/AWS/850/900 MHz • Universal quad-band GSM/GPRS/EDGE 850/900/1800/1900 MHz |
LTE Data Rate | • 20 MHz bandwidth: 100 Mbps DL, 50 Mbps UL • 10 MHz bandwidth: 50 Mbps DL, 25 Mbps UL |
HSPA Data Rate | 42 Mbps DL, 5.76 Mbps UL (Category 24, 6) |
EDGE Data Rate | 237 kbps DL, 237 kbps UL (Class 10, 12) |
GPRS Data Rate | 85.6 kbps DL, 42.8 kbps UL |
• LAN Interface | |
Number of Ports | 1 |
Speed | 10/100 Mbps, auto MDI/MDIX |
Connector | 8-pin RJ45 |
• Interface | |
Cellular Antenna Connectors | 2, SMA (female), MIMO for LTE, antenna diversity for WCDMA |
GNSS | 1 SMA (female), GPS (1575.42 MHz), GLONASS (1602 MHz) |
Console Port | RS-232 (RJ45) |
LED Indicators | PWR1, PWR2, READY, FAULT, CELLULAR SIGNAL, SIM1, SIM2, 2G, 3G, 4G, GPS, TX/RX |
Ground Screw | M5 |
Reset Button | Power Reset/Factory Default Reset |
• I/O Interface | |
Alarm Contact | 1 relay output with current carrying capacity of 1 A @ 24 VDC |
Digital Inputs | 2 electrically isolated inputs• +13 to +30 V for state “1” • +3 to -30 V for state “0” |
• Software | |
Network Protocols | ICMP, DDNS, TCP/IP, UDP, DHCP, Telnet, DNS, SNMP, HTTP, HTTPS, SMTP, SNTP, ARP |
Routing/Firewall | NAT, port forwarding, IP/MAC/Port filtering |
VPN | • IPSec VPN: > Encryption: DES, 3DES, AES, MD5, SHA-1, DH2, DH5 > Authentication: PSK/X.509/RSA > GRE over IPsec • OpenVPN: > OpenVPN (Server / Client) > Tunnel mode (routing) and TAP mode (bridge) > Encryption: Blowfish CBC, DES CBC, DES-EDE3 CBC, AES-128/192/256 CBC • NAT-T, PFS, DPD • Throughput: > IPsec: 16 Mbps max.* > OpenVPN: 8 Mbps max.* > Concurrent VPN Tunnels: Max. of 5 (Responder/Initiator) |
• *The maximum throughput is determined using specific testing equipment; the actual throughput depends on the cellular connection environment and conditions. | |
Applications | Real COM, Reverse Real COM, TCP Server, TCP Client, UDP, RFC2217 |
Management Options | Remote SMS Control, SNMPv1/v2c/v3, Web / Telnet / Serial Console |
GPS | NMEA |
• Software Specifications (Moxa Proprietary) | |
GuaranLink | Dual-SIM, 4-tier heartbeat for reliable and persistent cellular connectivity |
OnCell Central Manager | A powerful tool that makes two sites configured with Private IP addresses to access each other over a public network. Capable large scale centralized device management up to 2000pcs device connection and 200 lines for data transfer. Provide Pie charts present device status and information in a clear and readable format and easy to manage, group, monitor, configure, and upgrade the firmware of all your devices from OnCell Central Manager |
Wireless Search Utility | Simple device configuration and management |
• SIM Interface | |
Number of SIMs | 2, full-sized (1FF) |
• Serial Interface | |
Number of Ports | 1 |
Serial Standards | RS-232/422/485, software selectable |
Connector | DB9 male |
• Serial Communication Parameters | |
Data Bits | 5, 6, 7, 8 |
Stop Bits | 1, 1.5, 2 (when parity = None) |
Parity | None, Even, Odd, Space, Mark |
Baudrate | 75 bps to 921.6 kbps |
• Serial Signals | |
RS-232 | TxD, RxD, RTS, CTS, DTR, DSR, GND |
RS-422 | Tx+, Tx-, Rx+, Rx-, GND |
RS-485-4w | Tx+, Tx-, Rx+, Rx-, GND |
RS-485-2w | Data+, Data-, GND |
• Physical Characteristics | |
Housing | Metal, providing IP30 protection |
Weight | 492 g (1.08 lb) |
Dimensions | 126 x 30 x 107.5 mm (4.96 x 1.18 x 4.23 in) |
• Environmental Limits | |
Operating Temperature | Standard Models: 0 to 55°C (32 to 131°F) Wide Temp. Models:-30 to 70°C (-22 to 158°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
• Power Requirements | |
Number of Power Inputs | 2 (terminal block), redundant dual inputs |
Input Voltage | 12 to 48 VDC |
Input Current | 0.7 A @ 12 VDC; 0.2 A @ 48 VDC |
Reverse Polarity Protection | Present |
• Standards and Certifications | |
Safety | UL 60950-1 |
Hazardous Location | ATEX Zone 2, IECEx |
EMC | EN 61000-6-2/6-4 |
EMI | CISPR 22, FCC Part 15B Class A |
EMS | IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV IEC 61000-4-5 Surge: Power: 1 kV; Signal: 0.5 kV IEC 61000-4-6 CS: 10 V; 150 kHz to 80 MHz IEC 61000-4-8: 30 A/m continuous, 300 A/m for 3 s |
Freefall | IEC 60068-2-32 |
Vibration | IEC 60068-2-6 |
Shock | IEC 60068-2-27 |
Radio | > FCC ID N7NMC7355 > EN 301 489-1, EN 301 489-7, EN 301 511/4 |
• MTBF (mean time between failures) | |
Time | > 528,596 hrs |
Standard | Telcordia SR332 |
Model No. | Description | |
---|---|---|
OnCell G3150A-LTE-US | Industrial LTE cellular gateway, B2/B4/B5/B13/B17/B25, 0 to 55°C operating temperature | |
OnCell G3150A-LTE-US-T | Industrial LTE cellular gateway, B2/B4/B5/B13/B17/B25, -30 to 70°C operating temperature | |
OnCell G3150A-LTE-EU | Industrial LTE cellular gateway, B1/B3/B7/B8/B20, 0 to 55°C operating temperature | |
OnCell G3150A-LTE-EU-T | Industrial LTE cellular gateway, B1/B3/B7/B8/B20, -30 to 70°C operating temperature |
Wireless Antenna Cable
Model No. | Description | |
---|---|---|
A-CRF-SMSF-R3-100 | Cellular magnetic-base SMA connector with 1-meter RF cable |
Cellular Antennas
Model No. | Description | |
---|---|---|
ANT-LTE-ANF-04 | Full-band GSM/GPRS/EDGE/UMTS/HSPA/LTE, 4 dBi, omni-directional IP66 outdoor antenna | |
ANT-LTEUS-ASM-01 | GSM/GPRS/EDGE/UMTS/HSPA/LTE, 1 dBi, omni-directional, rubber duck antenna | |
ANT-LTE-ASM-02 | GPRS/EDGE/UMTS/HSPA/LTE, 2 dBi, omni-directional, rubber duck antenna |
Antennas
Model No. | Description | |
---|---|---|
ANT-GPS-OSM-05-3M | 26 dBi, 1572 MHz, L1 band antenna for GPS |
Learn how the LTE gateways help your long-distance application secure and easy. This application includes information on Moxa’s OnCell LTE products and how them assist with intelligent transportation systems, power automation, and water treatment automation.
White Paper: Choosing a Cellular Network Management Solution that Works for You
The biggest challenge that industries face today is designing a network infrastructure that can meet the constantly evolving industrial communication needs. Industrial networks are heterogeneous communication platforms that have evolved over time to cater to the multifaceted needs of its users. In addition to providing a core network infrastructure, industrial networks must also support the communication needs of the increasing number of devices that are added to the edge networks each day. In this white paper we look at the role of cellular networks in industrial edge networks and discuss how to choose a good cellular network management solution.