Features and Benefits 

  • Dual cellular operator backup with dual-SIM GuaranLink for reliable cellular connectivity
  • Rugged hardware design well suited for hazardous locations(ATEX Zone 2/IECEx)
  • VPN secure connection capability with IPSec, GRE, and OpenVPN protocols
  • Industrial design with dual-power inputs and built-in DI/DO support
  • Power isolation design for better device protection against harmful electrical interference

Introduction 

The OnCell G3150A-LTE is a reliable, secure, LTE gateway with state-ofthe-art global LTE coverage. This LTE cellular gateway provides a more reliable connection to your serial connection and Ethernet network for cellular applications.

To enhance industrial reliability, the OnCell G3150A-LTE features isolated power inputs, which together with high-level EMS and widetemperature support give the OnCell G3150A-LTE the highest level of device stability for any rugged environment. In addition, with dual-SIM GuaranLink and dual power inputs, the OnCell G3150A-LTE supports network redundancy to ensure uninterrupted connectivity.

The OnCell G3150A-LTE also comes with a 3-in-1 serial port for serial over LTE cellular network communication. Use the OnCell G3150A-LTE to collect data and exchange data with serial devices.

High-Speed Remote Gateway with VPN and Network Security

• Multi-band support

• Secure and reliable VPN support with NAT/ OpenVPN / GRE/ IPsec functionality

•Complies with the following cybersecurity standards:

IACS Components: IEC 62443-4-2 Level 1

IACS (Industrial Automation and Control Systems)

Industrial Isolation and Redundancy Design

• Dual power inputs for power redundancy

• Dual-SIM support for cellular connection redundancy

• Power isolation for power source insulation protection

• 4-tier GuaranLink for reliable cellular connectivity

• -30 to 70°C wide operating temperature support

• Cellular Interface
StandardsGSM/GPRS/EDGE/UMTS/HSPA/LTE
Band OptionsEU Band:
• B1 (2100 MHz) / B3 (1800 MHz) / B7 (2600 MHz) / B8 (900 MHz) / B20 (800 MHz)
• UMTS/HSPA 2100/1900/850/800/900 MHz
US Band:
• B2 (1900 MHz) / B4 (AWS) / B5 (850 MHz) / B13 (700 MHz) / B17 (700 MHz) / B25 (1900 MHz)
• UMTS/HSPA 2100/1900/AWS/850/900 MHz
• Universal quad-band GSM/GPRS/EDGE 850/900/1800/1900 MHz
LTE Data Rate• 20 MHz bandwidth: 100 Mbps DL, 50 Mbps UL
• 10 MHz bandwidth: 50 Mbps DL, 25 Mbps UL
HSPA Data Rate42 Mbps DL, 5.76 Mbps UL (Category 24, 6)
EDGE Data Rate237 kbps DL, 237 kbps UL (Class 10, 12)
GPRS Data Rate85.6 kbps DL, 42.8 kbps UL
• LAN Interface
Number of Ports1
Speed10/100 Mbps, auto MDI/MDIX
Connector8-pin RJ45
• Interface
Cellular Antenna Connectors2, SMA (female), MIMO for LTE, antenna diversity for WCDMA
GNSS1 SMA (female), GPS (1575.42 MHz), GLONASS (1602 MHz)
Console PortRS-232 (RJ45)
LED IndicatorsPWR1, PWR2, READY, FAULT, CELLULAR SIGNAL, SIM1, SIM2, 2G, 3G, 4G, GPS, TX/RX
Ground ScrewM5
Reset ButtonPower Reset/Factory Default Reset
• I/O Interface
Alarm Contact1 relay output with current carrying capacity of 1 A @ 24 VDC
Digital Inputs2 electrically isolated inputs• +13 to +30 V for state “1”
• +3 to -30 V for state “0”
• Software
Network ProtocolsICMP, DDNS, TCP/IP, UDP, DHCP, Telnet, DNS, SNMP, HTTP, HTTPS, SMTP, SNTP, ARP
Routing/FirewallNAT, port forwarding, IP/MAC/Port filtering
VPN• IPSec VPN:
> Encryption: DES, 3DES, AES, MD5, SHA-1, DH2, DH5
> Authentication: PSK/X.509/RSA
> GRE over IPsec
• OpenVPN:
> OpenVPN (Server / Client)
> Tunnel mode (routing) and TAP mode (bridge)
> Encryption: Blowfish CBC, DES CBC, DES-EDE3 CBC, AES-128/192/256 CBC
• NAT-T, PFS, DPD
• Throughput:
> IPsec: 16 Mbps max.*
> OpenVPN: 8 Mbps max.*
> Concurrent VPN Tunnels: Max. of 5 (Responder/Initiator)
• *The maximum throughput is determined using specific testing equipment; the actual throughput depends on the cellular connection environment and conditions.
ApplicationsReal COM, Reverse Real COM, TCP Server, TCP Client, UDP, RFC2217
Management OptionsRemote SMS Control, SNMPv1/v2c/v3, Web / Telnet / Serial Console
GPSNMEA
• Software Specifications (Moxa Proprietary)
GuaranLinkDual-SIM, 4-tier heartbeat for reliable and persistent cellular connectivity
OnCell Central ManagerA powerful tool that makes two sites configured with Private IP addresses to access each other over a public network. Capable large scale centralized device management up to 2000pcs device connection and 200 lines for data transfer. Provide Pie charts present device status and information in a clear and readable format and easy to manage, group, monitor, configure, and upgrade the firmware of all your devices from OnCell Central Manager
Wireless Search UtilitySimple device configuration and management
• SIM Interface
Number of SIMs2, full-sized (1FF)
• Serial Interface
Number of Ports1
Serial StandardsRS-232/422/485, software selectable
ConnectorDB9 male
• Serial Communication Parameters
Data Bits5, 6, 7, 8
Stop Bits1, 1.5, 2 (when parity = None)
ParityNone, Even, Odd, Space, Mark
Baudrate75 bps to 921.6 kbps
• Serial Signals
RS-232TxD, RxD, RTS, CTS, DTR, DSR, GND
RS-422Tx+, Tx-, Rx+, Rx-, GND
RS-485-4wTx+, Tx-, Rx+, Rx-, GND
RS-485-2wData+, Data-, GND
• Physical Characteristics
HousingMetal, providing IP30 protection
Weight492 g (1.08 lb)
Dimensions126 x 30 x 107.5 mm (4.96 x 1.18 x 4.23 in)
• Environmental Limits
Operating TemperatureStandard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models:-30 to 70°C (-22 to 158°F)
Storage Temperature-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)
• Power Requirements
Number of Power Inputs2 (terminal block), redundant dual inputs
Input Voltage12 to 48 VDC
Input Current0.7 A @ 12 VDC; 0.2 A @ 48 VDC
Reverse Polarity ProtectionPresent
• Standards and Certifications
SafetyUL 60950-1
Hazardous LocationATEX Zone 2, IECEx
EMCEN 61000-6-2/6-4
EMICISPR 22, FCC Part 15B Class A
EMSIEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV
IEC 61000-4-5 Surge: Power: 1 kV; Signal: 0.5 kV
IEC 61000-4-6 CS: 10 V; 150 kHz to 80 MHz
IEC 61000-4-8: 30 A/m continuous, 300 A/m for 3 s
FreefallIEC 60068-2-32
VibrationIEC 60068-2-6
ShockIEC 60068-2-27
Radio> FCC ID N7NMC7355
> EN 301 489-1, EN 301 489-7, EN 301 511/4
• MTBF (mean time between failures)
Time> 528,596 hrs
StandardTelcordia SR332

Available Models

 Model No.Description
OnCell G3150A-LTE-USIndustrial LTE cellular gateway, B2/B4/B5/B13/B17/B25, 0 to 55°C operating temperature
OnCell G3150A-LTE-US-TIndustrial LTE cellular gateway, B2/B4/B5/B13/B17/B25, -30 to 70°C operating temperature
OnCell G3150A-LTE-EUIndustrial LTE cellular gateway, B1/B3/B7/B8/B20, 0 to 55°C operating temperature
OnCell G3150A-LTE-EU-TIndustrial LTE cellular gateway, B1/B3/B7/B8/B20, -30 to 70°C operating temperature

Optional Accessories

Wireless Antenna Cable

 Model No.Description
A-CRF-SMSF-R3-100Cellular magnetic-base SMA connector with 1-meter RF cable

Cellular Antennas

 Model No.Description
ANT-LTE-ANF-04Full-band GSM/GPRS/EDGE/UMTS/HSPA/LTE, 4 dBi, omni-directional IP66 outdoor antenna
ANT-LTEUS-ASM-01GSM/GPRS/EDGE/UMTS/HSPA/LTE, 1 dBi, omni-directional, rubber duck antenna
ANT-LTE-ASM-02GPRS/EDGE/UMTS/HSPA/LTE, 2 dBi, omni-directional, rubber duck antenna

Antennas

 Model No.Description
ANT-GPS-OSM-05-3M26 dBi, 1572 MHz, L1 band antenna for GPS

Application Note: Remote Access Made Secure and Easy-LTE Gateways Application Note

Learn how the LTE gateways help your long-distance application secure and easy. This application includes information on Moxa’s OnCell LTE products and how them assist with intelligent transportation systems, power automation, and water treatment automation.

 White Paper: Choosing a Cellular Network Management Solution that Works for You

The biggest challenge that industries face today is designing a network infrastructure that can meet the constantly evolving industrial communication needs. Industrial networks are heterogeneous communication platforms that have evolved over time to cater to the multifaceted needs of its users. In addition to providing a core network infrastructure, industrial networks must also support the communication needs of the increasing number of devices that are added to the edge networks each day. In this white paper we look at the role of cellular networks in industrial edge networks and discuss how to choose a good cellular network management solution.

backtotop