Features

  • 4-port RS-232/422/485 serial interface
  • Supports up to 5 managed Ethernet switch ports (fiber available with some models)
  • DNP3 and Modbus protocols supported
  • IEC 61850-3, IEEE 1613 compliant (for power substations)
  • Ethernet redundancy with Turbo Ring/Chain and RSTP/STP supported
  • Real COM/TTY drivers for Windows and Linux
  • Supports IEC 61850 MMS protocol
  • Security features based on IEC-62443/NERC CIP
  • -40 to 85°C wide operating temperature

Overview

The NPort S9450I series 4-port RS-232/422/485 device servers, which come with a built-in full-function managed Ethernet switch, are designed specifically for the harsh environmental conditions found in electrical substations. With both fiber and wire Ethernet ports supported, the combination of device server plus Ethernet switch gives users the ability to easily install, manage, and maintain the NPort S9450I itself, as well as attached serial devices.

Electromagnetic Compatibility for Harsh Substation Environments

The NPort S9000 series supports a high level of surge protection to prevent damage from the types of power surges and EMI one finds in electrical substations and industrial automation applications. Combined with a -40 to 85°C operating temperature range and galvanized steel housing, the NPort S9000 is suitable for a wide range of industrial environoments.

Another plus is the NPort S9000’s dual power supplies, which provide both redundancy, as well as a wide range of voltage inputs. The WV models accept a power 24/48 VDC power input (ranging from 18 to 72 VDC), and the HV modesl accept a power input of 88 to 300 VDC and 85 to 264 VAC.

Power SCADA with IEC 61850 MMS for Easy Maintenance

The current trend in power SCADA applications is to control and monitor both IT devices (switches, routers, etc.) and IEDs (sensors, actuators, etc.) with the MMS protocol. Contrast this with the more traditional management approach of using SNMP for IT devices and MMS for IEDs. In fact, SIs may even need to manage a variety of legacy devices that use proprietary communications protocols. The NPort S9000 device servers are the world’s first device servers to integrate MMS into an IT-type device designed specifically for power SCADA applications. The NPort S9000 even supports using MMS to monitor serial communications between the S9000 and the legacy devices.

Supports Modbus/DNP3 Protocol Gateway

The NPort S9000 series provides maximum flexibility for integrating industrial Modbus/DNP3 networks of all types and sizes. The NPort S9000 is designed to integrate Modbus TCP, ASCII, and RTU devices in almost any master/slave combination, including simultaneous serial and Ethernet masters. The NPort S9000 device servers also support protocol conversion between DNP3 serial and DNP3 IP. All models are ruggedly constructed and are DIN-rail mountable.

Cybersecurity Features Based on IEC-62443

The NPort S9450I series has security features based on IEEE 62443/NERC CIP to provide a high level of cybersecurity. Protecting mission-critical networks from cyber attacks is a high-priority for industrial automation applications, which can suffer large losses due to extended network downtime.

Ring Redundancy at the Device Level

Device-level communication networks for industrial automation are very critical since they are used to control and monitor device processes. The reliability of these communications depends on ring redundancy at the device level, which is designed to provide fast network fault detection and reconfiguration to support the most demanding control applications. The NPort S9000 series integrates a full-function NPort device server with an industrial switch to carry serial and Ethernet devices at the same time. In addition, the NPort S9000 can also achieve ring redundancy with standard STP/RSTP and Moxa’s proprietary Turbo Ring or Turbo Chain 2 redundancy protocols. This all-in-one design can be used to optimize and simplify your device network and enhance reliability.

• General Specifications
• Port Summary
Serial Ports4 RS-232/422/485 ports
Ethernet Switch PortsNPort S9450I all copper models: 5 RJ45 copper ports
NPort S9450I copper/fiber models: 3 RJ45 copper ports, 2 fiber ports
Magnetic Isolation Protection1.5 kV built in
Console Ports1 (10-pin RJ45 connector)
• Physical Characteristics
HousingMetal
Weight2.54 kg (5.60 lb)
Dimensions80 x 160 x 109 mm (3.15 x 6.30 x 4.29 in)
• Environmental Limits
Operating Temperature-40 to 85°C (-40 to 185°F)
Storage Temperature-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)
• Power Requirements
Input VoltageWV models: 24/48 VDC (18 to 72 VDC)
HV models: 110/220 VAC/VDC (88 to 300 VDC, 85 to 264 VAC)
Input Current520 mA @ 24 VDC
80 mA @ 110 VDC
• Standards and Certifications
SafetyUL 508, UL 61010
EMCEN 61000-6-2/61000-6-4
EMICISPR 22, FCC Part 15B Class A
EMSIEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power 6 kV; Signal: 4 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
IEC 61000-4-8
Hazardous LocationUL/cUL Class I Division 2 Groups A/B/C/D
• Warranty
Warranty Period5 years
DetailsSee www.moxa.com/warranty
• Device Server Specifications
• Serial Interface
Number of Ports4
Serial StandardsRS-232/422/485
ConnectorDB9 male
Serial Line Protection2 kV isolation protection
RS-485 Data Direction ControlADDC® (Automatic Data Direction Control)
Console PortDedicated RS-232 console port (10-pin RJ45)
• Serial Communication Parameters
Data Bits5, 6, 7, 8
Stop Bits1, 1.5, 2
ParityNone, Even, Odd, Space, Mark
Flow ControlRTS/CTS and XON/XOFF
Baudrate50 bps to 921.6 Kbps
• Serial Signals
RS-232TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422Tx+, Tx-, Rx+, Rx-, GND
RS-485-4wTx+, Tx-, Rx+, Rx-, GND
RS-485-2wData+, Data-, GND
Digital Input2 inputs with the same ground, but electrically isolated from the electronics• +13 to +30 V for state “1”
• -30 to +3 V for state “0”
• Max. input current: 8 mA
• Software
Configuration OptionsCommand Line Interface (CLI) through Serial/Telnet/SSH, Web Console (HTTP/HTTPS), Windows Utility
Windows Real COM DriversWindows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded
Fixed TTY DriversSCO Unix, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X
Linux Real TTY DriversLinux 2.4.x, 2.6.x, 3.x
Operation ModesReal COM, TCP Server, TCP Client, UDP, RFC2217, Modbus, DNP3, DNP3 Raw Socket
ManagementSNMP MIB-II, IEC 61850 MMS
• Reliability
Alert ToolsBuilt-in buzzer and RTC (real-time clock)
Automatic Reboot TriggerBuilt-in WDT (watchdog timer)
• MTBF (mean time between failures)
Time347,436 hrs
StandardTelcordia (Bellcore) Standard TR/SR
• Ethernet Switch Specifications
• Ethernet Interface
StandardsIEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for Flow Control
IEEE 802.1D for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1x for Authenti
Network ProtocolsICMP, IPv4, TCP, UDP, ARP, Telnet, DNS, HTTP, SMTP, SNTP, IGMPv1/v2, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, DHCP Option 82, BootP, TFTP, SNTP, SMTP, RARP, GMRP, LACP, RMON
MIBMIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
Flow ControlIEEE 802.3x flow control, back pressure flow control interface
• Switch Properties
Priority Queues4
Max. Number of Available VLANs64
VLAN ID RangeVID 1 to 4094
IGMP Groups256
Cybersecurity• Security features based on IEC 62443/NERC CIP
• Supports port access control list: MAC, 802.1x authentication
• Supports RADIUS, TACACS+
• Supports Syslog for system/event
• Optical Fiber Interface
Table
• Switch Interface
RJ45 Ports10/100BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection
Alarm Contact2 relay outputs with current carrying capacity of 1A @ 24 VDC

Available Models

Model No.Description
NPort S9450I-WV-T4-port RS-232/422/485 rugged device server, 5 10/100M Ethernet ports, 24/48 VDC, -40 to 85°C operating temperature
NPort S9450I-HV-T4-port RS-232/422/485 rugged device server, 5 10/100M Ethernet ports, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
NPort S9450I-2M-SC-WV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with SC connectors, 24/48 VDC, -40 to 85°C operating temperature
NPort S9450I-2M-SC-HV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with SC connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
NPort S9450I-2M-ST-WV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with ST connectors, 24/48 VDC, -40 to 85°C operating temperature
NPort S9450I-2M-ST-HV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with ST connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
NPort S9450I-2S-SC-WV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with SC connectors, 24/48 VDC, -40 to 85°C operating temperature
NPort S9450I-2S-SC-HV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with SC connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature
NPort S9450I-2S-ST-WV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with ST connectors, 24/48 VDC, -40 to 85°C operating temperature
NPort S9450I-2S-ST-HV-T4-port RS-232/422/485 rugged device server, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with ST connectors, 88-300 VDC or 85-264 VAC, -40 to 85°C operating temperature

backtotop
b-chuyn-i-4-cng-rs232-485-422-sang-ethernet-nport-s9450i