ICF-1150 Series

Industrial RS-232/422/485 to fiber converters

L20150323172512

Features and Benefits

  • 3-way communication: RS-232, fiber, and RS-422/485
  • Rotary switch to change the pull high/low resistor value
  • Extend RS-232/422/485 transmission up to:
    • 40 km with single-mode
    • 5 km with multi-mode
  • 3-way isolation protection (for “I” models only)
  • -40 to 85°C wide temperature range models available 
  • C1D2, ATEX, and IECEx certified for harsh industrial environments

 

Three-Way Communication

The ICF-1150 series support 2 serial ports, with a DB9 connector for RS-232 communication and a removable terminal block for RS-422 or RS-485 communication. The 3 ports (2 serial ports and one fiber port) are completely independent. When an ICF-1150 converter receives data from any one port, it will send the data out through the other 2 ports. For example, once the ICF-1150 converter receives a command from the remote master through the fiber port, it will convert the signal and send the command through the RS-232 and RS-422/485 ports at the same time. If the user is monitoring a system running on an RS-485 network, there is no need to use an additional RS-232 to RS-485 converter to connect the laptop computer’s serial port to the RS-485 bus.

Rotary Switch for Setting the Pull High/Low Resistor

The RS-485 interface supports multi-drop or daisy-chain connections, which system engineers will use to connect serial devices such as meters, RTUs, and readers, together on the same bus. Since the number of serial devices on the same bus will cause the impedance of the data line to increase, the ICF-1150 allows users to tune the pull high/low resistor. Just rotate the switch to the appropriate value without removing the ICF-1150 from the DIN rail.

• Optical-Fiber Side
Fiber ConnectorSC or ST
Fiber Cable Requirements
Ring TransmissionHalf-duplex
Point-to-Point TransmissionHalf-duplex or full-duplex
• RS-232/422/485 Side
RS-232 SignalsTxD, RxD, GND
RS-422 SignalsTxD+, TxD-, RxD+, RxD-, GND
RS-485-4w SignalsTxD+, TxD-, RxD+, RxD-, GND
RS-485-2w SignalsData+, Data-, GND
Baudrate50 bps to 921.6 kbps
Isolation2 kV RMS isolation per I/O port for 1 minute
• Physical Characteristics
HousingMetal
Dimensions30.3 x 70 x 115 mm (1.19 x 2.76 x 4.53 in)
Weight330 g (0.73 lb)
• Environmental Limits
Operating TemperatureStandard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Storage Temperature-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)
• Power Requirements
Input Voltage12 to 48 VDC
Input CurrentICF-1150: 127 mA @ 12 VDC
ICF-1150I: 163 mA @ 12 VDC
Voltage Reversal ProtectionProtects against V+/V- reversal
Overcurrent Protection1.1 A (protects against two signals shorted together)
• Standards and Certifications
SafetyUL 508
Hazardous LocationUL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2 EEx nC IIC, IECEx
EMCEN 55032/24
EMICISPR 32, FCC Part 15B Class B
EMSEN 61000-4-2 (ESD): Contact: 8 kV; Air: 15 kV
EN 61000-4-3 (RS): 80 MHz to 1 GHz: 3 V/m
EN 61000-4-4 (EFT): Power: 4 kV; Signal: 2 kV
EN 61000-4-5 (Surge): Power: 4 kV; Signal: 0.5 kV
EN 61000-4-6 (CS): 150 kHz to 80 MHz: 3 V/m
EN 61000-4-8 (PFMF)
Green ProductRoHS, CRoHS, WEEE
FreefallIEC 60068-2-32
• MTBF (mean time between failures)
Time792,085 hrs
StandardTelcordia (Bellcore), GB
Water and Dust ProofIP30
• Warranty
Warranty Period5 years
DetailsSee www.moxa.com/warranty

Available Models

Model No.Description
ICF-1150I-M-SCIndustrial RS-232/422/485 to multimode fiber converter, SC connector, 2 KV isolation, 0 to 60°C operating temperature
ICF-1150I-M-SC-TIndustrial RS-232/422/485 to multimode fiber converter, SC connector, 2 KV isolation, -40 to 85°C operating temperature
ICF-1150I-M-STIndustrial RS-232/422/485 to multimode fiber converter, ST connector, 2 KV isolation, 0 to 60°C operating temperature
ICF-1150I-M-ST-TIndustrial RS-232/422/485 to multimode fiber converter, ST connector, 2 KV isolation, -40 to 85°C operating temperature
ICF-1150I-S-SCIndustrial RS-232/422/485 to single mode fiber converter, SC connector, 2 KV isolation, 0 to 60°C operating temperature
ICF-1150I-S-SC-TIndustrial RS-232/422/485 to single mode fiber converter, SC connector, 2 KV isolation, -40 to 85°C operating temperature
ICF-1150I-S-STIndustrial RS-232/422/485 to single mode fiber converter, ST connector, 2 KV isolation, 0 to 60°C operating temperature
ICF-1150I-S-ST-TIndustrial RS-232/422/485 to single mode fiber converter, ST connector, 2 KV isolation, -40 to 85°C operating temperature
ICF-1150-M-SCIndustrial RS-232/422/485 to multimode fiber converter, SC connector, 0 to 60°C operating temperature
ICF-1150-M-SC-TIndustrial RS-232/422/485 to multimode fiber converter, SC connector, -40 to 85°C operating temperature
ICF-1150-M-STIndustrial RS-232/422/485 to multimode fiber converter, ST connector, 0 to 60°C operating temperature
ICF-1150-M-ST-TIndustrial RS-232/422/485 to multimode fiber converter, ST connector, -40 to 85°C operating temperature
ICF-1150-S-SCIndustrial RS-232/422/485 to single mode fiber converter, SC connector, 0 to 60°C operating temperature
ICF-1150-S-SC-TIndustrial RS-232/422/485 to single mode fiber converter, SC connector, -40 to 85°C operating temperature
ICF-1150-S-STIndustrial RS-232/422/485 to single mode fiber converter, ST connector, 0 to 60°C operating temperature
ICF-1150-S-ST-TIndustrial RS-232/422/485 to single mode fiber converter, ST connector, -40 to 85°C operating temperature
ICF-1150-M-SC-IEXIndustrial RS-232/422/485 to multimode fiber converter, SC connector, IECEx, 0 to 60°C operating temperature
ICF-1150-M-ST-IEXIndustrial RS-232/422/485 to multimode fiber converter, ST connector, IECEx, 0 to 60°C operating temperature
ICF-1150-S-SC-IEXIndustrial RS-232/422/485 to single mode fiber converter, SC connector, IECEx, 0 to 60°C operating temperature
ICF-1150-S-ST-IEXIndustrial RS-232/422/485 to single mode fiber converter, ST connector, IECEx, 0 to 60°C operating temperature
ICF-1150I-M-SC-IEXIndustrial RS-232/422/485 to multimode fiber converter, SC connector, 2 kV isolation, IECEx, 0 to 60°C operating temperature
ICF-1150I-M-ST-IEXIndustrial RS-232/422/485 to multimode fiber converter, ST connector, 2 kV isolation, IECEx, 0 to 60°C operating temperature
ICF-1150I-S-SC-IEXIndustrial RS-232/422/485 to single mode fiber converter, SC connector, 2 kV isolation, IECEx, 0 to 60°C operating temperature
ICF-1150I-S-ST-IEXIndustrial RS-232/422/485 to single mode fiber converter, ST connector, 2 kV isolation, IECEx, 0 to 60°C operating temperature
ICF-1150-M-SC-T-IEXIndustrial RS-232/422/485 to multimode fiber converter, SC connector, IECEx, -40 to 85°C operating temperature
ICF-1150-M-ST-T-IEXIndustrial RS-232/422/485 to multimode fiber converter, ST connector, IECEx, -40 to 85°C operating temperature
ICF-1150-S-SC-T-IEXIndustrial RS-232/422/485 to single mode fiber converter, SC connector, IECEx, -40 to 85°C operating temperature
ICF-1150-S-ST-T-IEXIndustrial RS-232/422/485 to single mode fiber converter, ST connector, IECEx, -40 to 85°C operating temperature
ICF-1150I-M-SC-T-IEXIndustrial RS-232/422/485 to multimode fiber converter, SC connector, 2 kV isolation, IECEx, -40 to 85°C operating temperature
ICF-1150I-M-ST-T-IEXIndustrial RS-232/422/485 to multimode fiber converter, ST connector, 2 kV isolation, IECEx, -40 to 85°C operating temperature
ICF-1150I-S-SC-T-IEXIndustrial RS-232/422/485 to single mode fiber converter, SC connector, 2 kV isolation, IECEx, -40 to 85°C operating temperature
ICF-1150I-S-ST-T-IEXIndustrial RS-232/422/485 to single mode fiber converter, ST connector, 2 kV isolation, IECEx, -40 to 85°C operating temperature

Optional Accessories

 DIN Rail Power Supplies

Model No.Description
DR-452445W/2A DIN-rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input, -10 to 50°C operating temperature

Dimensions

Pin Assignment

backtotop