TN-5516A Series

EN 50155 16-port managed Ethernet switches

switch-cong-nghiep-managed-EN50155-16-cong

Features and Benefits

  • Isolated power with wide 24 to 110 VDC power supply range
  • Complies with all EN 50155 mandatory test items*
  • -40 to 75°C operating temperature range 
  • Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches), and STP/RSTP/MSTP for network redundancy
    *This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here: www.moxa.com/doc/specs/EN_50155_Compliance.pdf

Introduction

The ToughNet TN-5516A series M12 managed Ethernet switches are designed for railway applications, such as rolling stock, and wayside installations. The TN series switches use M12 and other circular connectors to ensure tight, robust connections, and guarantee reliable operation against environmental disturbances, such as vibration and shock. The TN-5516A series Ethernet switches provide 16 Fast Ethernet M12 ports. In addition, the 24 to 110 VDC wide power input range and isolated power inputs not only allow you to use the same type of power source at different sites around the globe, but also increase the reliability of your communications system. In addition, the -40 to 75°C operating temperature and IP54-rated waterproof enclosure allow deployment in harsh environments. Moreover, the TN-5500A series is compliant with the mandatory sections of EN 50155, covering operating temperature, power input voltage, surge, ESD and vibration, making the switches suitable for a variety of industrial applications.

• Technology
StandardsIEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
IEEE 802.3x for Flow Control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid Spanning Tree Protocol
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication
IEEE 802.3ad for Port Trunk with LACP
• Software Features
ManagementIPv4/IPv6, SNMP v1/v2c/v3, Telnet, LLDP, Port Mirror, Syslog, RMON, BootP, DHCP Server/Client, DHCP Option 66/67/82, TFTP, SNTP, SMTP, RARP, HTTP, HTTPS, SNMP inform, Flow Control, Back pressure flow control
Filter802.1Q, Port-Based VLAN, GVRP, IGMPv1/v2, GMRP, Static Multicast
Redundancy ProtocolsSTP/RSTP, MSTP, Turbo Ring v1/v2, Turbo Ring v2 with DRC, Turbo Chain, Link Aggregation
SecurityRADIUS, TACACS+, SSL, SSH, Port Lock, Broadcast Storm, Rate Limit
Time ManagementSNTP, NTP Server/Client, IEEE1588 PTP (software-based)
Industrial ProtocolsEtherNet/IP
Quality of Service802.1P/Default/DSCP Mapping
MIBMIB-II, Ethernet-like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
• Switch Properties
Priority Queues4
Max. Number of VLANs64
VLAN ID RangeVID 1 to 4094
IGMP Groups256
• Interface
Fast EthernetFront cabling, M12 D-coded 4-pin female connector, 10/100BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection
Console PortM12 A-coding 5-pin male connector
Alarm Contact2 relay outputs in one M12 A-coding 5-pin male connector with current carrying capacity of 1A @ 30 VDC
• Power Requirements
Input Voltage24/36/48/72/96/110 VDC
Operating Voltage16.8 to 137.5 VDC
Input Current0.39 A @ 24 VDC; 0.09 A @ 110 VDC
Overload Current ProtectionPresent
ConnectionM23 connector
Reverse Polarity ProtectionPresent
• Physical Characteristics
IP RatingAluminium alloy, IP54 protection (optional protective caps available for unused ports)
Dimensions250 x 175.8 x 76.0 mm (9.84 x 6.92 x 2.99 in)
Weight2,138 g (4.71 lb)
InstallationPanel mounting, DIN-rail mounting (with optional kit: DK-DC50131)
• Environmental Limits
Operating Temperature-40 to 75°C (-40 to 167°F)
Storage Temperature-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)
VibrationIEC 60068-2-6, 2-17.8 Hz: ±1.6 mm; 17.8-500 Hz: 2 g; 2 hours/axis
ShockIEC 60068-2-27, 20 g / 11 ms
Ingress ProtectionIEC 60529, IP54
Altitude2,000 m 
Note: Please contact Moxa if you require products guaranteed to function at
higher altitudes
• Standards and Certifications
SafetyUL/cUL 508, EN 60950-1 (LVD)
EMCEN 55032, EN 55024
EMICISPR 32, FCC Part 15B Class A
EMSIEC 61000-4-2 ESD: Contact 6 kV; Air 8 kV
IEC 61000-4-3 RS: 20 V/m (80 MHz to 1 GHz)
IEC 61000-4-4 EFT: Power 2 kV; Signal 2 kV
IEC 61000-4-5 Surge: Power 2 kV; Signal 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8
Rail Traffic (for panel-mounting installations)EN 50155*, EN 50121-4, EN 45545-2
*This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here: www.moxa.com/doc/specs/EN_50155_Compliance.pdf
• *Please contact Moxa or a Moxa distributor for details.
ShockIEC 61373
FreefallIEC 60068-2-32
VibrationEN 50155, IEC 61373
• MTBF (mean time between failures)
Time722,721 hrs
StandardTelcordia SR332, GB, 25°C 
Note: Please check Moxa’s website for the most up-to-date certification status.

Available Models

 Model No.Description
TN-5516A-WV-TManaged Ethernet switch with 16 10/100BaseT(X) ports with M12 connectors, dual redundant power inputs (24-110 VDC), -40 to 75°C operating temperature
TN-5516A-WV-CT-TManaged Ethernet switch with 16 10/100BaseT(X) ports with M12 connectors, dual redundant power inputs (24-110 VDC), -40 to 75°C operating temperature, conformal coating model

White Paper: Optimized Ethernet Redundancy for Inter-Consist Networks

Network redundancy is a critical factor in ensuring passenger safety and journey reliability in onboard railway communications for both intra-consist and inter-consist Ethernet networks. In addition, railway operators are looking for ways to more efficiently allocate resources and serve passenger demands. For example, metropolitan rail services may want to run trains with fewer consists during off-peak hours but longer trains with more consists during rush hour. Railway operators can also serve multiple markets and conserve track assets by connecting multiple consists with different destinations into one train if they will travel along the same route for at least part of the journey. 

This white paper describes how Dynamic Ring Coupling helps railway operators provide seamless onboard Ethernet redundancy with both rapid recovery times and automatic Ethernet switch configuration even when consists are rearranged mid-journey.

2015 Railway Application Guide 

Moxa has provided key communications, data control, and computing infrastructure for dozens of successful major railway projects around the world. Metro, mainline, high speed rail, and conventional rolling stock applications on six continents. This brochure examines some key application scenarios and how Moxa addresses today’s industrial challenges.

This brochure covers the following applications:

  • Ethernet Train Backbone
  • Onboard CCTV
  • Passenger Wi-Fi
  • Passenger Information System
  • Communication-based Train Control (CBTC)
  • Wayside Communication System
  • Condition Monitoring for Turnouts
 

backtotop