Features and Benefits

  • 85M-1602-T: 16 digital inputs, 24 VDC, sink/source type
  • 85M-2600-T: 16 digital outputs, 24 VDC, sink-type
  • 85M-3800-T: 8 analog inputs, 4 to 20 mA
  • 85M-3810-T: 8 analog inputs, 0 to 10 VDC
  • 85M-3801-T: 8 analog inputs, 4 to 20 mA, 40 kHz
  • 85M-3811-T: 8 analog inputs, 0 to 10 VDC, 40 kHz
  • 85M-5401-T: 4 serial ports (RS-232/422/485)
  • 85M-6600-T: 6 RTDs

Introduction

Moxa’s 85M series modules can be installed in both ioPAC 8500 and ioPAC 8600 systems. Modules are available with DI/Os, AIs, Fast AIs, and serial interfaces, giving users a wide choice of options to choose from. Enough options are available to allow users to select the best I/O combination for their target application. All 85M modules are designed for railway industry applications, and as such are compliant with EN 50121-3-2, EN 50121-4, and EN 50155. In addition, the modules support a wide operating temperature range of -40 to 75°C.

85M-1602-T Specifications
• Inputs and Outputs
Digital Inputs16 channels
Isolation3k VDC or 2k Vrms
• Digital Input
Sensor TypeWet contact (NPN or PNP), dry contact
I/O ModeDI, Counter or Frequncy
Dry Contact• On: short to GND
• Off: open
Wet Contact (DI to COM)• Off: 0 to 3 VDC
• On: 10 to 30 VDC
Common Type8 points per COM
Counter Frequency5 kHz
Digital Filtering Time IntervalSoftware selectable (by 0.1 ms)
• Physical Characteristics
WiringI/O cable, 16 AWG (max.)
ConnectorSpring-type terminal block
• Environmental Limits
Operating Temperature-40 to 75°C (-40 to 176°F)
• Power Requirements
Input Current363.6 mA @ 3.3 VDC
• MTBF (mean time between failures)
Time1,132,561 hrs
StandardTelcordia SR332
85M-2600-T Specifications
• Inputs and Outputs
Digital Outputs16 channels
Isolation3k VDC or 2k Vrms
• Digital Output
TypeSink
I/O ModeDO or PWM
Pulse Output Frequency5 kHz
Over-Voltage Protection45 VDC
Over-Current Protection2.6 A (4 channels @ 650 mA)
Over-Temperature Shutdown175°C (typical), 150°C (min.)
Current Rating200 mA per channel
• Physical Characteristics
WiringI/O cable, 16 AWG (max.)
ConnectorSpring-type terminal block
• Environmental Limits
Operating Temperature-40 to 75°C (-40 to 176°F)
• Power Requirements
Input Current257.6 mA @ 3.3 VDC
• MTBF (mean time between failures)
Time792,571 hrs
StandardTelcordia SR332
85M-3800-T Specifications
• Inputs and Outputs
Analog Inputs8 channels
Isolation3k VDC or 2k Vrms
• Analog Input
TypeDifferential
Resolution16 bits
I/O Mode4 to 20 mA (wire off)
Accuracy±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C
Sampling Rate• All channels: 100 samples/sec
• Per channel: 12.5 samples/sec
Input Impedance125 ohms (min.)
• Physical Characteristics
WiringI/O cable, 16 AWG (max.)
ConnectorSpring-type terminal block
• Environmental Limits
Operating Temperature-40 to 75°C (-40 to 176°F)
• Power Requirements
Input Current318.2 mA @ 3.3 VDC
• MTBF (mean time between failures)
Time1,512,906 hrs
StandardTelcordia SR332
85M-3810-T Specifications
• Inputs and Outputs
Analog Inputs8 channels
Isolation3k VDC or 2k Vrms
• Analog Inputs
TypeDifferential
Resolution16 bits
I/O Mode0 to 10 VDC
Accuracy±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C
Sampling Rate• All channels: 100 samples/sec
• Per channel: 12.5 samples/sec
Input Impedance200 kilo-ohms (min.)
• Physical Characteristics
WiringI/O cable, 16 AWG (max.)
ConnectorSpring-type terminal block
• Environmental Limits
Operating Temperature-40 to 75°C (-40 to 176°F)
• Power Requirements
Input Current315.2 mA @ 3.3 VDC
• MTBF (mean time between failures)
Time1,530,690 hrs
StandardTelcordia SR332
85M-3801-T Specifications
• Inputs and Outputs
Analog Inputs8 channels
Isolation3k VDC or 2k Vrms
• Analog Input
TypeDifferential
Resolution16 bits
I/O Mode4 to 20 mA (wire off)
Historical Data Buffering60 KB per channel, 6-second data buffer at 5 kHz
Accuracy±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C
Sampling Rate• All channels: 40k samples/sec
• Per channel: 5k samples/sec
Input Impedance125 ohms (min.)
• Physical Characteristics
WiringI/O cable, 16 AWG (max.)
ConnectorSpring-type terminal block
• Environmental Limits
Operating Temperature-40 to 75°C (-40 to 176°F)
• Power Requirements
Input Current378.8 mA @ 3.3 VDC
• MTBF (mean time between failures)
Time1,426,112 hrs
StandardTelcordia SR332
85M-3811-T Specifications
• Inputs and Outputs
Analog Inputs8 channels
Isolation3k VDC or 2k Vrms
• Analog Inputs
TypeDifferential
Resolution16 bits
I/O Mode0 to 10 VDC
Historical Data Buffering60 KB per channel, 6-second data buffer at 5 kHz
Accuracy±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C
Sampling Rate• All channels: 40k samples/sec
• Per channel: 5k samples/sec
Input Impedance20 mega-ohms (min.)
• Physical Characteristics
WiringI/O cable, 16 AWG (max.)
ConnectorSpring-type terminal block
• Environmental Limits
Operating Temperature-40 to 75°C (-40 to 176°F)
• Power Requirements
Input Current378.8 mA @ 3.3 VDC
• MTBF (mean time between failures)
Time1,426,112 hrs
StandardTelcordia SR332
85M-6600-T Specifications
• Inputs and Outputs
RTD Inputs6 channels
Isolation3k VDC or 2k Vrms
• RTDs
Input Type• PT50, PT100, PT200, PT500 (-200 to 850°C)
• PT1000 (-200 to 350°C)
• JPT100, JPT200, JPT500 (-200 to 640°C)
• JPT1000 (-200 to 350°C)
• NI100, NI200, NI500 (-60 to 250°C)
• NI1000 (-60 to 150°C)
• NI120 (-80 to 260°C)
• Resistance of 310, 620
Sampling Rate (single channel)• All channels: 12 samples/sec
• Per channel: 2 samples/sec
Resolution0.1°C or 0.1 ohms
Accuracy±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C
Input Impedance625 kilo-ohms (min.)
WiringI/O cable, 16 AWG (max.)
ConnectorSpring-type terminal block
• Environmental Limits
Operating Temperature-40 to 75°C (-40 to 176°F)
• Power Requirements
Input Current201.5 mA @ 3.3 VDC
• MTBF (mean time between failures)
Time571,446 hrs
StandardTelcordia SR332
85M-6810-T Specifications
• Inputs and Outputs
Analog Inputs8 channels
Isolation3k VDC or 2k Vrms
• Thermocouples
Sensor TypeJ (0 to 750°C), K (-200 to 1250°C), T (-200 to 350°C), E (-200 to 900°C), R (-50 to 1600°C), S (-50 to 1760°C), B (600 to 1700°C), N (-200 to 1300°C)
Millivolt Type• Mode: ±78.126 mV, ±39.062 mV, ±19.532 mV
• Fault and over-voltage protection: -35 to +35 VDC (power off); -25 to +30 VDC (power on)
Sampling Rate (single channel)• All channels: 12 samples/sec
• Per channel: 1.5 samples/sec
Resolution16 bits
Accuracy±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C
Input Impedance1 mega-ohm (min.)
WiringI/O cable, 16 AWG (max.)
ConnectorSpring-type terminal block
• Environmental Limits
Operating Temperature-40 to 75°C (-40 to 176°F)
• Power Requirements
Input Current175.5 mA @ 3.3 VDC
• MTBF (mean time between failures)
Time2,324,891 hrs
StandardTelcordia SR332
85M-5401-T Specifications
• Serial Communication
Interface4 RS-232/422/485 ports, software selectable (DB44 female)
Isolation3k VDC or 2k Vrms
Note: DB44 to 4-port DB9 cable included in the package.
• Serial Communication Parameters
ParityNone, Even, Odd
Data Bits7, 8
Stop Bits1, 2
Flow ControlRTS/CTS, XON/XOFF
Baudrate300 bps to 921.6 kbps
• Serial Signals
RS-232TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422Tx+, Tx-, Rx+, Rx-, GND
RS-485-4wTx+, Tx-, Rx+, Rx-, GND
RS-485-2wData+, Data-, GND
• Physical Characteristics
ConnectorDB44 female
• Environmental Limits
Operating Temperature-40 to 75°C (-40 to 176°F)
• Power Requirements
Input Current375.8 mA @ 3.3 VDC
• MTBF (mean time between failures)
Time596,611 hrs
StandardTelcordia SR332
Common Specifications
• Power Requirements
Input Voltage24 VDC (9 to 48 VDC)
• Environmental Limits
Storage Temperature-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)
ShockIEC 60068-2-27
VibrationIEC 60068-2-6
• Standards and Certifications
SafetyUL 508
EMCEN 55032/24
EMIFCC Part 15 Subpart B Class A, CISPR 32
EMSIEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS:
80 MHz to 1000 MHz: 3 V/m
1400 MHz to 2100 MHz: 3 V/m
2100 MHz to 2700 MHz: 1 V/m
IEC 61000-4-4 EFT: Power: 1 kV; Signal 0.5 kV
IEC 61000-4-5 Surge: Power: 2 kV (L-PE), 1 kV (L-L);
Rail TrafficEN 50155*, EN 50121-3-2, EN 50121-4
*Complies with a portion of EN 50155 specifications.
• Warranty
Warranty Period5 years
DetailsSee www.moxa.com/warranty

Available Models

Model No.Description
85M-1602-TioPAC 8500 I/O module with 16 DIs, 24 VDC sink/source type, -40 to 75°C operating temperature
85M-2600-TioPAC 8500 I/O module with 16 DOs, 24 VDC sink type, -40 to 75°C operating temperature
85M-3800-TioPAC 8500 I/O module with 8 AIs, 4 to 20 mA, -40 to 75°C operating temperature
85M-3810-TioPAC 8500 I/O module with 8 AIs, 0 to 10 V, -40 to 75°C operating temperature
85M-3801-TioPAC 8500 I/O module with 8 AIs, 4 to 20 mA, 40 kHz, -40 to 75°C operating temperature
85M-3811-TioPAC 8500 I/O module with 8 AIs, 0 to 10 V, 40 kHz, -40 to 75°C operating temperature
85M-6600-TioPAC 8500 I/O module with 6 RTDs, -40 to 75°C operating temperature
85M-6810-TioPAC 8500 I/O module with 8 TCs, -40 to 75°C operating temperature
85M-5401-TioPAC 8500 communication module with 4-port Serial, DB44 connectors, -40 to 75°C operating temperature

Fast Track Integration for Wayside Condition Monitoring and Preventive Maintenace

This white paper will discuss how railway operators are adopting increasingly sophisticated condition-based maintenance regimes to control costs and improve track performance, some of the key difficulties system integrators need to overcome when deploying wayside condition monitoring systems for railway preventive maintenance, and how using a single condition monitoring platform can save time and costs for deployment and maintenance.

Railway Preventive Maintenance Solutions Flyer

See how Moxa’s ioPAC 8500 RTU controllers make railway preventive maintenance easy. The RTUs provide extremely accurate data, giving engineers the information they need to identify anomalous conditions, before failures occur. The ioPAC 8500 RTUs are also designed to work reliably in harsh environments, and modules can be easily replaced to shorten system downtime.

backtotop
iopac-8500-series-expansion-modules-safenergy-i-din-moxa-ti-vit-nam