ICS-G7848A/ICS-G7850A/ICS-G7852A Series

48G/48G+2 10GbE/48G+4 10GbE-port Layer 3 full Gigabit modular managed Ethernet switches

moxa-viet-nam-switch-ethernet-cong-nghiep-managed-48-cong-gigabit

Features and Benefits  

  • Up to 48 Gigabit Ethernet ports plus 4 10G Ethernet ports
  • Up to 52 optical fiber connections (SFP slots)
  • Up to 48 PoE+ ports with external power supply (with IM-G7000A- 4PoE module)
  • Fanless, -10 to 60°C operating temperature range
  • Modular design for maximum flexibility and hassle-free future expansion
  • Hot swap interface and power modules for continuous operation
  • Turbo Ring and Turbo Chain (recovery time < 50 ms @ 250 switches), RSTP/STP, and MSTP for network redundancy
  • Isolated redundant power inputs with universal 110/220 VAC power supply range
  • Supports MXstudio for easy, visualized industrial network management
  • V-ON™ ensures millisecond-level multicast data and video network recovery

Introduction

Process automation and transportation automation applications combine data, voice, and video, and consequently require high performance and high reliability. The ICS-G7848A/G7850A/G7852A series full Gigabit backbone switches’ modular design makes network planning easy, and allows greater flexibility by letting you install up to 48 Gigabit Ethernet ports plus 4 10 Gigabit Ethernet ports. The ICS-G7848A/G7850A/G7852A series also supports Layer 3 routing functionality to facilitate the deployment of applications across networks, making them ideal for large scale industrial networks. The ICS-G7848A/G7850A/G7852A’s full Gigabit capability increases bandwidth to provide high performance and the ability to quickly transfer large amounts of video, voice, and data across a network. The switches support the Turbo Ring, Turbo Chain, and RSTP/STP redundancy protocols, and are fanless and come with an isolated redundant power supply to increase system reliability and the availability of your network backbone.

• Technology
StandardsIEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseSX/LX/LHX/ZX
IEEE 802.3ae for 10 Gigabit Ethernet
IEEE 802.3af/at for PoE/PoE+ output
IEEE 802.3x for Flow Control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid Spanning Tree Protocol
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication
IEEE 802.3ad for Port Trunk with LACP
• Software Features
ManagementIPv4, SNMP v1/v2c/v3, LLDP, Port Mirror, DDM, RMON, DHCP Server/Client, DHCP Option 66/67/82, BootP, TFTP, SMTP, RARP, Telnet, Syslog, SNMP Inform, Flow Control, Back Pressure Flow Control
Filter802.1Q VLAN, Q-in-Q VLAN, GVRP, IGMP v1/v2/v3, GMRP
Redundancy ProtocolsSTP, RSTP, MSTP, Turbo Ring v1/v2, Turbo Chain, Link Aggregation
SecurityRADIUS, TACACS+, SSL, SSH, Broadcast Storm Protection, Port Lock, Access Control Lists (ICS-G7800A series only)
Unicast RoutingStatic Routing, RIPV1/V2, OSPF (ICS-G7800A series)
Multicast RoutingDVMRP, PIM-DM, PIM-SM, PIM-SSM (ICS-G7800A series)
Time ManagementSNTP, NTP Server/Client, IEEE 1588v2 PTP (software-based)
Industrial ProtocolsEtherNet/IP, Modbus/TCP
MIBMIB-II, Ethernet-like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Groups 1, 2, 3, 9
Routing RedundancyVRRP (ICS-G7800A series)
• Switch Properties
Priority Queues8
Max. Number of VLANs256
VLAN ID RangeVID 1 to 4094
IGMP Groups4096
MAC Table Size16 K
Packet Buffer Size12 Mbit
DRAM Size128 MB
Flash Size16 MB
Jumbo Frame Size9.6 KB
• Interface
Gigabit Ethernet12 slots for 4-port interface modules
• 10/100/1000BaseT(X), or
• PoE+ 10/100/1000BaseT(X), or
• 100/1000BaseSFP slots 
Note: See the IM-G7000A datasheet for Gigabit Ethernet module product information.
10 Gigabit Ethernet2 or 4 10GbE SFP+ slots (ICS-G7850A and ICS-G7852A only)
Console PortUSB-serial console (Type B connector)
Storage PortUSB storage (Type A connector for ABC-02-USB)
Alarm Contact1 relay output with current carrying capacity of 2 A @ 30 VDC
Digital Inputs1 input with the same ground, but electrically isolated from the electronics.
• +13 to +30 V for state “1”
• -30 to +1 V for state “0”
• Max. input current: 8 mA
• Power Requirements
Input Voltage110/220 VAC
Operating Voltage85 to 264 VAC
Input CurrentICS-G7848A: Max. 0.87/0.51 A @ 110/220 VAC 
ICS-G7850A: Max. 0.94/0.55 A @ 110/220 VAC
ICS-G7852A: Max. 1.01/0.58 A @ 110/220 VAC
Overload Current ProtectionPresent
Reverse Polarity ProtectionPresent
• Physical Characteristics
IP RatingIP30 protection
Dimensions440 x 176 x 523.8 mm (17.32 x 6.93 x 20.62 in)
Weight12.9 kg (28.5 lb)
Installation19-inch rack mounting
• Environmental Limits
Operating Temperature-10 to 60°C (14 to 140°F)
Storage Temperature-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)
• Standards and Certifications
SafetyUL 60950-1, EN 60950-1
EMCEN 55032/24
EMICISPR 32, FCC Part 15B Class A
EMSIEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: Signal: 10 V
IEC 61000-4-8
Rail TrafficEN 50121-4
ShockIEC 60068-2-27
FreefallIEC 60068-2-32
VibrationIEC 60068-2-6 
Note: Please check Moxa’s website for the most up-to-date certification status.
• MTBF (mean time between failures)
TimeICS-G7848A: 314,973 hrs
ICS-G7850A: 282,329 hrs
ICS-G7852A: 274,488 hrs
StandardTelcordia (Bellcore), GB

Available Models

 Model No.Description
ICS-G7848A-HV-HVLayer 3 full Gigabit modular managed Ethernet switch system with 12 slots for 4-port Gigabit Ethernet interface modules, 2 isolated power supplies (85 to 264 VAC), for a total of up to 48G ports, 0 to 60°C operating temperature
ICS-G7850A-2XG-HV-HVLayer 3 full Gigabit modular managed Ethernet switch system with 2 10GbE SFP+ slots, 12 slots for 4-port Gigabit Ethernet interface modules, 2 isolated power supplies (85 to 264 VAC), for a total of up to 48G + 2 10GbE ports, 0 to 60°C operating temperature
ICS-G7852A-4XG-HV-HVLayer 3 full Gigabit modular managed Ethernet switch system with 4 10GbE SFP+ slots, 12 slots for 4-port Gigabit Ethernet interface modules, 2 isolated power supplies (85 to 264 VAC), for a total of up to 48G + 4 10GbE ports, 0 to 60°C operating temperature

Compatible Modules

IM-G7000A Series

 Model No.Description
IM-G7000A-4GTXGigabit Ethernet interface module with 4 10/100/1000BaseT(X) ports, 0 to 60°C operating temperature
IM-G7000A-4GSFPGigabit Ethernet interface module with 4 100/1000BaseSFP slots, 0 to 60°C operating temperature
IM-G7000A-4PoEGigabit Ethernet PoE+ interface module with 4 10/100/1000BaseT(X) ports, -10 to 60°C operating temperature

Optional Accessories

Trial Software

 Model No.Description
MXviewIndustrial network management software designed for converged automation networks
MXconfigIndustrial network configuration tool
MXstudio Industrial Network Management SuiteIndustrial network management suite for installation, operation, maintenance, and diagnostics

Ensure Nonstop IP Surveillance with an Optimized Industrial Ethernet Network

If your CCTV system uses multicast transmission over a redundant ring, then even if your ring redundancy protocol is able to activate backup paths in a fraction of a second when a disconnection occurs, it could still take more than 2 minutes for your multicast video streams to recover. This is because a number of different protocols—including IGMP (Internet Group Management Protocol) and PIM-DM (Protocol Independent Multicast – Dense Mode)—are implemented to transmit your video packets around the network, and these standard protocols are not designed for mission-critical applications. In this white paper, we show how implementing an appropriate non-standard proprietary protocol can optimize your network for video stream transmission, and in this way overcome IGMP’s sluggishness.

Video_Always_On_Whitepaper
FAQ: Is Your Network Infrastructure Ready for the IIoT?

The Industrial Internet of Things (IIoT) trend aims to improve efficiency and productivity by connecting different devices together as well as collecting and analyzing large volumes of data to offer accurate information. However, before reaping the benefits of the IIoT, users need to ensure that the correct infrastructure is in place. To make sure your network is ready for the IIoT, check out five of the most frequently mentioned questions.

FAQ_cover
Ensure Nonstop IP Surveillance with an Optimized Industrial Ethernet Network

If your CCTV system uses multicast transmission over a redundant ring, then even if your ring redundancy protocol is able to activate backup paths in a fraction of a second when a disconnection occurs, it could still take more than 2 minutes for your multicast video streams to recover. This is because a number of different protocols—including IGMP (Internet Group Management Protocol) and PIM-DM (Protocol Independent Multicast – Dense Mode)—are implemented to transmit your video packets around the network, and these standard protocols are not designed for mission-critical applications. In this white paper, we show how implementing an appropriate non-standard proprietary protocol can optimize your network for video stream transmission, and in this way overcome IGMP’s sluggishness.

V-ON_WP
V-ON Success Story Flyer

With the growing demand of safety-critical surveillance in industrial automation applications, engineers are facing the challenges of building a reliable network to ensure non-stop video transmission. In this success story, we give details about how Moxa’s advanced V-ON technology helps build a video-optimized network for a tramway project.

V-ON_Story

V-ON Technology: Ensure Video Stays Online for Mission-Critical Surveillance

Enhance control room reliability with Moxa industrial rackmount switches

backtotop
ics-g7848a-ics-g7850a-ics-g7852a-series-safenergy-i-din-moxa-ti-vit-nam