8+2G multiport industrial secure router with switch/firewall/NAT/VPN
The EDR-810 is a highly integrated industrial multiport secure router with firewall/NAT/VPN and managed Layer 2 switch functions. It is designed for Ethernet-based security applications in sensitive remote control or monitoring networks, and it provides an electronic security perimeter for the protection of critical cyber assets such as pumping/ treatment systems in water stations, DCS systems in oil and gas applications, and PLC/SCADA systems in factory automation. The EDS-810 series includes the following cybersecurity features:
The EDR-810’s “WAN Routing Quick Setting” provides an easy way for users to set up WAN and LAN ports to create a routing function in four steps. In addition, the EDR-810’s “Quick Automation Profile” gives engineers a simple way to configure the firewall filtering function with general automation protocols, including EtherNet/IP, Modbus TCP, EtherCAT, FOUNDATION Fieldbus, and PROFINET. Users can easily create a secure Ethernet network from a user-friendly web UI with a single click, and the EDR-810 is capable of performing deep Modbus TCP packet inspection. Wide temperature range models that operate reliably in hazardous, -40 to 75°C environments are also available.
• Technology | |
Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3ab for 1000BaseT(X) IEEE 802.3z for 1000BaseX IEEE 802.1Q for VLAN tagging IEEE 802.3ad for port trunk |
Protocols | SNMP v1/v2c/v3, DHCP server/client, TFTP, NTP/SNTP server/client, HTTP, HTTPS, Telnet, SSH, IPSec, L2TP, IGMP v1/v2/v3, QoS/CoS/ToS, Radius, RSTP/STP, LLDP, DDNS, Proxy ARP |
Routing | Static routing, RIP V1/V2, OSPFThroughput: 10000 packets per second (max. 100 Mbps) |
Routing Redundancy | VRRP |
Multicast Routing | Static, DVMRP, PIM-SM/SSM |
Broadcast Forwarding | IP directed broadcast, broadcast forwarding |
Redundancy | STP/RSTP, Turbo Ring V2, Ring Coupling, and Dual Homing |
Flow Control | IEEE 802.3x flow control, back pressure flow control |
• Security Functions | |
Firewall | Features: • Stateful inspection • Router firewall and transparent (bridge) firewall • Filter: IP and MAC address, ports, ICMP, DDoS, Ethernet protocols • Deep Packet Inspection: Modbus TCP/UDP • Quick Automation Profiles: EtherCAT, EtherNet/IP, F |
DoS and DDoS Protection | Null Scan, Xmas Scan, NMAP-Xmas Scan, SYN/FIN Scan, FIN Scan, NMAP-ID Scan, SYN/RST Scan, NEW-Without-SYN Scan, ICMP-Death, SYN-Flood, ARP-Flood |
NAT | N-to-1, 1-to-1, bidirectional 1-to-1, and port forwarding |
IPSec VPN | Protocols: • IPSec • L2TP (server) • PPTP (client) Encryption: • DES, 3DES, AES-128, AES-192, AES-256 Authentication: • RSA (key size: 1024-bit, 2048-bit) • X.509 v3 certificate • MD5 and SHA (SHA-256) Throughput: • Max. 17 Mbps (Conditions: AES |
OpenVPN | Protocols: • OpenVPN (client and server), UDP and TCP • Tunnel mode (routing) and TAP mode (bridge) Encryption: • Blowfish CBC, DES CBC, DES-EDE3 CBC, AES-128/192/256 CBC Authentication: • User password by MD5 and SHA1 Throughput: • Max. 5 Mbps Co |
Real-Time Firewall / VPN Event Log | • Event Type: Firewall Event, VPN Event, System Security Event • Media: Local storage, Syslog server, and SNMP trap |
• Switch Properties | |
Max. Number of VLANs | 16 |
VLAN ID Range | 1 to 4094 |
IGMP Groups | 256 |
• Interface | |
RJ45 Ports | 10/100BaseT(X) auto negotiation speed |
Fiber Ports | 1000BaseSFP slot |
Console Port | Web/Telnet/SSH/CLI, and RS-232 serial console |
RESET button | Reset to default settings |
LED Indicators | STATE, PWR1, PWR2, FAULT, 10/100/1000M |
Alarm Contact | One relay output with current-carrying capacity of 1 A @ 24 VDC |
Digital Inputs | 1 2-contact terminal block• +13 to +30 V for state “1” • -30 to +3 V for state “0” • Max. input current: 8 mA |
• Power Requirements | |
Input Voltage | 12/24/48 VDC, redundant dual inputs |
Input Current | 0.32 A @ 24 V |
Overload Current Protection | Present |
Connection | Removable terminal block |
Reverse Polarity Protection | Present |
• Physical Characteristics | |
Housing | Metal |
Dimensions | 53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in) |
Weight | 830 g (2.10 lb) |
Installation | DIN-rail mounting, wall mounting (with optional kit) |
• Environmental Limits | |
Operating Temperature | Standard Models: -10 to 60°C (14 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
• Standards and Certifications | |
Safety | UL 508 |
EMC | EN 55032/24 |
Hazardous Location | UL/cUL Class I Division 2 Groups A/B/C/D |
EMI | CISPR 32, FCC Part 15B Class A |
EMS | IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: Signal: 10 V IEC 61000-4-8 |
Rail Traffic | EN 50121-4 |
Transportation | NEMA TS2 |
Shock | IEC 60068-2-27 |
Freefall | IEC 60068-2-32 |
Vibration | IEC 60068-2-6 |
• MTBF (mean time between failures) | |
Time | 981,954 hrs |
Standard | Telcordia (Bellcore), GB |
Model No. | Description | |
---|---|---|
EDR-810-2GSFP | 8+2G SFP industrial multiport secure router with Firewall/NAT, -10 to 60°C operating temperature | |
EDR-810-2GSFP-T | 8+2G SFP industrial multiport secure router with Firewall/NAT, -40 to 75°C operating temperature | |
EDR-810-VPN-2GSFP | 8+2G SFP industrial multiport secure router with Firewall/NAT/VPN, -10 to 60°C operating temperature | |
EDR-810-VPN-2GSFP-T | 8+2G SFP industrial multiport secure router with Firewall/NAT/VPN, -40 to 75°C operating temperature |
SFP-1G Series
Model No. | Description | |
---|---|---|
SFP-1G10ALC | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX 1310 nm, RX 1550 nm, 0 to 60°C operating temperature | |
SFP-1G10ALC-T | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX 1310 nm, RX 1550 nm, -40 to 85°C operating temperature | |
SFP-1G10BLC | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX 1550 nm, RX 1310 nm, 0 to 60°C operating temperature | |
SFP-1G10BLC-T | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX 1550 nm, RX 1310 nm, -40 to 85°C operating temperature | |
SFP-1G20ALC | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX 1310 nm, RX 1550 nm, 0 to 60°C operating temperature | |
SFP-1G20ALC-T | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX 1310 nm, RX 1550 nm, -40 to 85°C operating temperature | |
SFP-1G20BLC | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX 1550 nm, RX 1310 nm, 0 to 60°C operating temperature | |
SFP-1G20BLC-T | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX 1550 nm, RX 1310 nm, -40 to 85°C operating temperature | |
SFP-1G40ALC-T | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission; TX 1310 nm, RX 1550 nm, -40 to 85°C operating temperature | |
SFP-1G40BLC | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission; TX 1550 nm, RX 1310 nm, 0 to 60°C operating temperature | |
SFP-1G40BLC-T | WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission; TX 1550 nm, RX 1310 nm, -40 to 85°C operating temperature | |
SFP-1GEZXLC | SFP module with 1 1000BaseEZX port with LC connector for 110 km transmission, 0 to 60°C operating temperature | |
SFP-1GEZXLC-120 | SFP module with 1 1000BaseEZX port with LC connector for 120 km transmission, 0 to 60°C operating temperature | |
SFP-1GLHLC | SFP module with 1 1000BaseLH port with LC connector for 30 km transmission, 0 to 60°C operating temperature | |
SFP-1GLHLC-T | SFP module with 1 1000BaseLH port with LC connector for 30 km transmission, -40 to 85°C operating temperature | |
SFP-1GLHXLC | SFP module with 1 1000BaseLHX port with LC connector for 40 km transmission, 0 to 60°C operating temperature | |
SFP-1GLSXLC | SFP module with 1 1000BaseLSX port with LC connector for 2 km transmission, 0 to 60°C operating temperature | |
SFP-1GLSXLC-T | SFP module with 1 1000BaseLSX port with LC connector for 2 km transmission, -40 to 85°C operating temperature | |
SFP-1GLXLC | SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, 0 to 60°C operating temperature | |
SFP-1GLXLC-T | SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, -40 to 85°C operating temperature | |
SFP-1GSXLC | SFP module with 1 1000BaseSX port with LC connector for 0.5 km transmission, 0 to 60°C operating temperature | |
SFP-1GSXLC-T | SFP module with 1 1000BaseSX port with LC connector for 0.5 km transmission, -20 to 75°C operating temperature | |
SFP-1GZXLC | SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, 0 to 60°C operating temperature | |
SFP-1GZXLC-T | SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, -40 to 85°C operating temperature |
In this paper, we present important considerations for implementing network security and network security risk management. We also include information on how to develop mitigation strategies for specific problems and provide directions on how to choose the right industrial firewall to ensure safety and reliability for industrial networks
FAQ: Is Your Network Infrastructure Ready for the IIoT?
The Industrial Internet of Things (IIoT) trend aims to improve efficiency and productivity by connecting different devices together as well as collecting and analyzing large volumes of data to offer accurate information. However, before reaping the benefits of the IIoT, users need to ensure that the correct infrastructure is in place. To make sure your network is ready for the IIoT, check out five of the most frequently mentioned questions
edr-810-series-safenergy-i-din-moxa-ti-vit-nam