18-slot rackmount chassis managed media converter
The TRC-2190 series provides 18 slots for media converter modules from the CSM-400 series of Ethernet-to-fiber management modules. It also supports SNMP/web console for remote management and monitoring. A TRC-2190 chassis comes with one AC or DC power input, with an optional redundant power expansion module available for greater reliability. The TRC-2190 series’ power input module supports a fanless chassis design, as well as a -20 to 55°C operating temperature range.
• Ethernet Interface | |
Number of Ports | 2 |
Speed | 10/100 Mbps, auto MDI/MDIX |
Connector | 8-pin RJ45 |
Magnetic Isolation Protection | 1.5 kV built-in |
• USB Interface | |
Number of Ports | 1 |
USB Standard | USB 1.1/2.0 standard |
Connector | USB Type B |
• Software | |
Network Protocols | ICMP, IP, TCP, DHCP, Telnet, DNS, SNMP V1/V2c/V3, HTTP, SMTP |
Configuration Options | SNMP/HTTP/Telnet/USB/SSH/HTTPS |
• Physical Characteristics | |
Housing | SECC (1.2 mm) |
Dimensions | 440 x 260 x 77 mm (18.6 x 11 x 3.3 in) |
Weight | 5.2 kg (11.4 lbs), with one power module installed |
Number of Slots | 18 slots on the front for slide-in modules, 2 slots on the back for power supply modules |
• Environmental Limits | |
Operating Temperature | -20 to 55°C (-4 to 131°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
• Power Requirements | |
Input Voltage | Universal 100 to 240 VAC (47 to 63 Hz) or ±48 VDC (36 to 53 VDC and -36 to -53 VDC) |
Power Consumption | Max. Output: 3.2A @ 36VDC |
• Standards and Certifications | |
Safety | UL 60950-1, EN 60950-1 |
EMC | CE, FCC |
EMI | EN 55032 Class A, FCC Part 15 Subpart B Class A |
EMS | EN 61000-4-2 (ESD) Contact: 4 kV; Air: 8 kV EN 61000-4-3 (RS) 80 MHz to 1 GHz: 3 V/m EN 61000-4-4 (EFT) Power: 1 kV; Signal: 0.5 kV EN 61000-4-5 (Surge) Power: 1 kV; Signal: 0.5 kV EN 61000-4-6 (CS) 150 kHz to 80 MHz: 3 V/m EN 61000-4-8 (PFMF) EN 6100 |
Green Product | RoHS, CRoHS, WEEE |
• MTBF (mean time between failures) | |
Time | 1,055,112 hrs |
Standard | Telcordia (Bellcore), GB |
• Warranty | |
Warranty Period | 5 years |
Details | See www.moxa.com/warranty |
Model No. | Description | |
---|---|---|
TRC-2190-AC | 2U rackmount chassis, with a single 110 to 240 VAC input, 18 slots on the front panel, and CSM-MN01 managed module | |
TRC-2190-DC48V | 2U rackmount chassis, with a single 36 to 53 VDC input, 18 slots on the front panel, and CSM-MN01 managed module | |
ME-10-T | 1 chassis slot, redundant 12 to 48 VDC power inputs |
Model No. | Description | |
---|---|---|
CSM-400-1213 | 10/100BaseT(X) to 100BaseFX slide-in management module converter, multi-mode ST connector, -20 to 55°C | |
CSM-400-1213-T | 10/100BaseT(X) to 100BaseFX slide-in management module converter, multi-mode ST connector, -40 to 75°C | |
CSM-400-1214 | 10/100BaseT(X) to 100BaseFX slide-in management module converter, multi-mode SC connector, -20 to 55°C | |
CSM-400-1214-T | 10/100BaseT(X) to 100BaseFX slide-in management module converter, multi-mode SC connector, -40 to 75°C | |
CSM-400-1218 | 10/100BaseT(X) to 100BaseFX slide-in management module converter, single-mode SC connector, -20 to 55°C | |
CSM-400-1218-T | 10/100BaseT(X) to 100BaseFX slide-in management module converter, single-mode SC connector, -40 to 75°C | |
CSM-400-1224 | 10/100BaseT(X) to 100BaseFX slide-in management module converter, WDM-A single-mode SC connector, -20 to 55°C | |
CSM-400-1224-T | 10/100BaseT(X) to 100BaseFX slide-in management module converter, WDM-A single-mode SC connector, -40 to 75°C | |
CSM-400-1225 | 10/100BaseT(X) to 100BaseFX slide-in management module converter, WDM-B single-mode SC connector, -20 to 55°C | |
CSM-400-1225-T | 10/100BaseT(X) to 100BaseFX slide-in management module converter, WDM-B single-mode SC connector, -40 to 75°C |
Model No. | Description | |
---|---|---|
PWR-2190-DC48V | Redundant power supply, 36 to 53 VDC | |
PWR-2190-AC | Redundant power supply, 110 to 240 VAC |
Model No. | Description | |
---|---|---|
Plate-1 | Face plate to cover unused front panel slots (required for all unused slots) |
trc-2190-series-safenergy-i-din-moxa-ti-vit-nam