Features and Benefits
The ToughNet TN-5308 series M12 unmanaged Ethernet switches are designed for industrial applications in harsh environments. The TN series switches use M12 connectors to ensure tight, robust connections, and guarantee reliable operation against environmental disturbances, such as vibration and shock. The TN-5308 series Ethernet switches provide 8 Fast Ethernet M12 ports, support IEEE 802.3/802.3u/802/3x with 10/100M, full/half-duplex, MDI/MDI-X auto-sensing, and provide an economical solution for your industrial Ethernet network. Models with an extended operating temperature range of -40 to 75°C are also available. The TN-5308 series Ethernet switches comply with those EN 50155 requirements that make products more suitable for rolling stock applications, including operating temperature, power input voltage, surge, ESD, and vibration, making the switches suitable for a variety of industrial applications.
• Technology | |
Standards | IEEE 802.3 for 10BaseTa IEEE 802.3u for 100BaseT(X) IEEE 802.3x for Flow Control |
Processing Type | Store and Forward |
• Interface | |
M12 Ports | 10/100BaseT(X) auto negotiation speed, F/H duplex mode and auto MDI/MDI-X connection |
• Power Requirements | |
Input Voltage | • TN-5308-LV: 12/24/36/48 VDC • TN-5308-MV: 72/96/110 VDC Note: Compliant with EN 50155 on 24/48/72/96/110 VDC |
Operating Voltage | • TN-5308-LV: 8.4 to 60 VDC • TN-5308-MV: 50.4 to 137.5 VDC |
Input Current | • TN-5308-LV: 0.19 A @ 12 VDC, 0.10 A @ 24 VDC, 0.054 A @ 48 VDC • TN-5308-MV: 0.033 A @ 72 VDC, 0.024 A @ 96 VDC, 0.021 A @ 110 VDC |
Connection | • TN-5308-LV: M12 connector • TN-5308-MV: M23 connector |
Reverse Polarity Protection | Present |
• Physical Characteristics | |
Housing | Metal |
IP Rating | IP40 protection |
Dimensions | TN-5308-LV: 60 x 216.6 x 36.1 mm (2.36 x 8.53 x 1.42 in) TN-5308-MV: 60 x 216.6 x 53.8 mm (2.36 x 8.53 x 2.12 in) |
Weight | TN-5308-LV: 485 g (1.07 lb) TN-5308-MV: 685 g (1.51 lb) |
Installation | Panel mounting, DIN-rail mounting (with optional kit: DK-TN-5308) |
• Environmental Limits | |
Operating Temperature | Standard Models: -25 to 60°C (-13 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
• Standards and Certifications | |
Safety | UL/cUL 508, EN 60950-1 (LVD) |
EMI | FCC Part 15 Subpart B Class A, EN 55032 Class A |
EMS | IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 |
Rail Traffic (for panel mounting installations) | EN 50155*, EN 50121-4, EN 45545-2 *Complies with a portion of EN 50155 specifications. |
Shock | EN 50155, IEC 61373 |
Freefall | IEC 60068-2-32 |
Vibration | EN 50155, IEC 61373 Note: Please check Moxa’s website for the most up-to-date certification status. |
• MTBF (mean time between failures) | |
Time | TN-5308-LV Series: 2,099,286 hrs TN-5308-MV Series: 2.590.858 hrs |
Standard | Telcordia SR332 |
Model No. | Description | |
---|---|---|
TN-5308-LV | Unmanaged Ethernet switch with 8 10/100BaseT(X) ports with M12 connectors, 7 ~ 60 VDC, -25 to 60°C operating temperature, M12 power cable | |
TN-5308-LV-T | Unmanaged Ethernet switch with 8 10/100BaseT(X) ports with M12 connectors, 7 ~ 60 VDC, -40 to 75°C operating temperature, M12 power cable | |
TN-5308-MV | Unmanaged Ethernet switch with 8 10/100BaseT(X) ports with M12 connectors, 50.4 ~ 154 VDC, -25 to 60°C operating temperature, M23 power cable | |
TN-5308-MV-T | Unmanaged Ethernet switch with 8 10/100BaseT(X) ports with M12 connectors, 50.4 ~ 154 VDC, -40 to 75°C operating temperature, M23 power cable |
Model No. | Description | |
---|---|---|
CBL-M23(FF6P)/Open-BK-100 IP67 | M23 Power Cords | |
CBL-M12(FF5P)/Open-100 IP67 | 1-meter A-coded M12-to-5-pin power cable, 5-pin female M12 connector, IP67-rated |
Model No. | Description | |
---|---|---|
A-CAP-M12M-M | Metal cap for M12 male connector | |
A-CAP-M12F-M | Metal Cap for M12 Female Connector |
Model No. | Description | |
---|---|---|
DK-TN-5308 | DIN Rail Mount Kit, 1 pcs of plates (174x60x12.8mm), 3 screws (PMS M3X30mm), 3 screws (PMS M3X4mm) |
Model No. | Description | |
---|---|---|
M12A-5P-IP68 | Field-installable A-coded screw-in sensor connector, female | |
M12D-4P-IP68 | Field-installable D-coded screw-in sensor connector, male |
White Paper: Optimized Ethernet Redundancy for Inter-Consist NetworksNetwork redundancy is a critical factor in ensuring passenger safety and journey reliability in onboard railway communications for both intra-consist and inter-consist Ethernet networks. In addition, railway operators are looking for ways to more efficiently allocate resources and serve passenger demands. For example, metropolitan rail services may want to run trains with fewer consists during off-peak hours but longer trains with more consists during rush hour. Railway operators can also serve multiple markets and conserve track assets by connecting multiple consists with different destinations into one train if they will travel along the same route for at least part of the journey. This white paper describes how Dynamic Ring Coupling helps railway operators provide seamless onboard Ethernet redundancy with both rapid recovery times and automatic Ethernet switch configuration even when consists are rearranged mid-journey. | |
2015 Railway Application GuideMoxa has provided key communications, data control, and computing infrastructure for dozens of successful major railway projects around the world. Metro, mainline, high speed rail, and conventional rolling stock applications on six continents. This brochure examines some key application scenarios and how Moxa addresses today’s industrial challenges. This brochure covers the following applications:
|