TN-5305 Series

50155 5-port IP67 unmanaged Ethernet switches

switch-cong-nghiep-unmanaged-EN50155-5-cong-IP67

Features and Benefits 

  • 10/100BaseT(X), 4-pin M12 (D-coded), F/H duplex mode, and auto MDI/MDI-X connection
  • IP67 rated housing protection
  • Power input: 12 to 45 VDC, 18 to 30 VAC
  • Complies with all EN 50155 mandatory test items*
  • -40 to 75°C operating temperature range (T models)
    *This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here: www.moxa.com/doc/specs/EN_50155_Compliance.pdf

Introduction

The TN-5305 series Ethernet switches are IP67-rated for tough industrial applications. By using M12 connectors, you can rest assured that Ethernet cables will connect tightly to the switch, and will be robust enough to protect your applications from external disturbances, such as the vibration and shock encountered in the transportation industry. The space-saving TN-5305 switches can be mounted virtually anywhere, and wide operating temperature (-40 to 75°C) models are also available for use in the most extreme weather conditions. The TN-5305 Series Ethernet switches comply with a portion of EN 50155 specifications, covering operating temperature, power input voltage, surge, ESD, and vibration, making the switches suitable for a variety of industrial applications.

• Technology
StandardsIEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
IEEE 802.3x for Flow Control
Processing TypeStore and Forward
• Software Features
Processing TypeStore and Forward
• Interface
M12 Ports10/100BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection
• Power Requirements
Input Voltage• 24/36 VDC
• 18 to 30 VAC (47 to 63 Hz)
NoteCompliant with EN 50155 on 24 VDC
Operating Voltage• 12 to 45 V
• 18 to 30 VAC (47 to 63 Hz)
Input Current• 0.28 A @ 24 VAC
• 0.10 A @ 24 VDC
• 0.08 A @ 36 VDC
Overload Current ProtectionPresent
Connection1 M12 socket (A-coded), single power input
Reverse Polarity ProtectionPresent
• Physical Characteristics
HousingPlastic
IP RatingIP67 protection
Dimensions60 x 125 x 29.6 mm (2.36 x 4.92 x 1.09 in)
Weight270 g (0.56 lb)
InstallationField-style mounting, DIN-rail mounting (with optional kit)
• Environmental Limits
Operating TemperatureStandard Models: -25 to 60°C (-13 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)
• Standards and Certifications
SafetyUL/cUL 508
EMIFCC Part 15 Subpart B Class A, EN 55032 Class A
EMSIEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8
Rail Traffic(for panel-mounting installations) EN 50155*, EN 50121-4
*This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click herewww.moxa.com/doc/specs/EN_50155_Compliance.pdf
ShockEN 50155, IEC 61373
FreefallIEC 60068-2-32
VibrationEN 50155, IEC 61373
Note: Please check Moxa’s website for the most up-to-date certification status.
• MTBF (mean time between failures)
Time3,451,678 hrs
StandardTelcordia SR332

Available Models

Model No.Description
TN-5305Unmanaged IP67-rated Ethernet switch with 5 10/100BaseT(X) ports with M12 connectors, -25 to 60°C operating temperature, M12 power cable
TN-5305-TUnmanaged IP67-rated Ethernet switch with 5 10/100BaseT(X) ports with M12 connectors, -40 to 75°C operating temperature, M12 power cable

Optional Accessories

DIN Rail Power Supplies

 Model No.Description
DR-452445W/2A DIN-rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input, -10 to 50°C operating temperature
MDR-60-2460W/2.5A DIN-Rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input, -20 to 70°C operating temperature
MDR-40-2440W/1.7A DIN-Rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input , -20 to 70°C operating temperature
DR-75-2475W/3.2A DIN-rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input, -10 to 60°C operating temperature
DR-120-24120W/5A DIN-rail 24 VDC power supply with universal 88 to 132 VAC or 176 to 264 VAC input by switch, or 248-370 VDC , -10 to 60°C operating temperature

Power Cords

 Model No.Description
CBL-M12(FF5P)/Open-100 IP671-meter A-coded M12-to-5-pin power cable, 5-pin female M12 connector, IP67-rated

Wireless Connector Cap

 Model No.Description
A-CAP-M12M-MMetal cap for M12 male connector
A-CAP-M12F-MMetal Cap for M12 Female Connector

Mounting Kits

 Model No.Description
DK-M12-305DIN Rail Mount Kit, 1 pcs of plates (125x60x4mm) with 3 screws (PMS M3X20mm), 1 pcs of plates (48.3x44x8.8mm) with 2 screws (FMS M3X4mm)

Connectors

 Model No.Description
M12A-5P-IP68Field-installable A-coded screw-in sensor connector, female
M12D-4P-IP68Field-installable D-coded screw-in sensor connector, male

White Paper: Optimized Ethernet Redundancy for Inter-Consist Networks

Network redundancy is a critical factor in ensuring passenger safety and journey reliability in onboard railway communications for both intra-consist and inter-consist Ethernet networks. In addition, railway operators are looking for ways to more efficiently allocate resources and serve passenger demands. For example, metropolitan rail services may want to run trains with fewer consists during off-peak hours but longer trains with more consists during rush hour. Railway operators can also serve multiple markets and conserve track assets by connecting multiple consists with different destinations into one train if they will travel along the same route for at least part of the journey. 

This white paper describes how Dynamic Ring Coupling helps railway operators provide seamless onboard Ethernet redundancy with both rapid recovery times and automatic Ethernet switch configuration even when consists are rearranged mid-journey.

2015 Railway Application Guide 

Moxa has provided key communications, data control, and computing infrastructure for dozens of successful major railway projects around the world. Metro, mainline, high speed rail, and conventional rolling stock applications on six continents. This brochure examines some key application scenarios and how Moxa addresses today’s industrial challenges.

This brochure covers the following applications:

  • Ethernet Train Backbone
  • Onboard CCTV
  • Passenger Wi-Fi
  • Passenger Information System
  • Communication-based Train Control (CBTC)
  • Wayside Communication System
  • Condition Monitoring for Turnouts
 

backtotop
tn-5305-series-safenergy-i-din-moxa-ti-vit-nam