The TN-5305 series Ethernet switches are IP67-rated for tough industrial applications. By using M12 connectors, you can rest assured that Ethernet cables will connect tightly to the switch, and will be robust enough to protect your applications from external disturbances, such as the vibration and shock encountered in the transportation industry. The space-saving TN-5305 switches can be mounted virtually anywhere, and wide operating temperature (-40 to 75°C) models are also available for use in the most extreme weather conditions. The TN-5305 Series Ethernet switches comply with a portion of EN 50155 specifications, covering operating temperature, power input voltage, surge, ESD, and vibration, making the switches suitable for a variety of industrial applications.
• Technology | |
Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3x for Flow Control |
Processing Type | Store and Forward |
• Software Features | |
Processing Type | Store and Forward |
• Interface | |
M12 Ports | 10/100BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection |
• Power Requirements | |
Input Voltage | • 24/36 VDC • 18 to 30 VAC (47 to 63 Hz) |
Note | Compliant with EN 50155 on 24 VDC |
Operating Voltage | • 12 to 45 V • 18 to 30 VAC (47 to 63 Hz) |
Input Current | • 0.28 A @ 24 VAC • 0.10 A @ 24 VDC • 0.08 A @ 36 VDC |
Overload Current Protection | Present |
Connection | 1 M12 socket (A-coded), single power input |
Reverse Polarity Protection | Present |
• Physical Characteristics | |
Housing | Plastic |
IP Rating | IP67 protection |
Dimensions | 60 x 125 x 29.6 mm (2.36 x 4.92 x 1.09 in) |
Weight | 270 g (0.56 lb) |
Installation | Field-style mounting, DIN-rail mounting (with optional kit) |
• Environmental Limits | |
Operating Temperature | Standard Models: -25 to 60°C (-13 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
• Standards and Certifications | |
Safety | UL/cUL 508 |
EMI | FCC Part 15 Subpart B Class A, EN 55032 Class A |
EMS | IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 |
Rail Traffic | (for panel-mounting installations) EN 50155*, EN 50121-4 *This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click herewww.moxa.com/doc/specs/EN_50155_Compliance.pdf |
Shock | EN 50155, IEC 61373 |
Freefall | IEC 60068-2-32 |
Vibration | EN 50155, IEC 61373 |
Note: Please check Moxa’s website for the most up-to-date certification status. | |
• MTBF (mean time between failures) | |
Time | 3,451,678 hrs |
Standard | Telcordia SR332 |
Model No. | Description | |
---|---|---|
TN-5305 | Unmanaged IP67-rated Ethernet switch with 5 10/100BaseT(X) ports with M12 connectors, -25 to 60°C operating temperature, M12 power cable | |
TN-5305-T | Unmanaged IP67-rated Ethernet switch with 5 10/100BaseT(X) ports with M12 connectors, -40 to 75°C operating temperature, M12 power cable |
DIN Rail Power Supplies
Model No. | Description | |
---|---|---|
DR-4524 | 45W/2A DIN-rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input, -10 to 50°C operating temperature | |
MDR-60-24 | 60W/2.5A DIN-Rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input, -20 to 70°C operating temperature | |
MDR-40-24 | 40W/1.7A DIN-Rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input , -20 to 70°C operating temperature | |
DR-75-24 | 75W/3.2A DIN-rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input, -10 to 60°C operating temperature | |
DR-120-24 | 120W/5A DIN-rail 24 VDC power supply with universal 88 to 132 VAC or 176 to 264 VAC input by switch, or 248-370 VDC , -10 to 60°C operating temperature |
Power Cords
Model No. | Description | |
---|---|---|
CBL-M12(FF5P)/Open-100 IP67 | 1-meter A-coded M12-to-5-pin power cable, 5-pin female M12 connector, IP67-rated |
Wireless Connector Cap
Model No. | Description | |
---|---|---|
A-CAP-M12M-M | Metal cap for M12 male connector | |
A-CAP-M12F-M | Metal Cap for M12 Female Connector |
Mounting Kits
Model No. | Description | |
---|---|---|
DK-M12-305 | DIN Rail Mount Kit, 1 pcs of plates (125x60x4mm) with 3 screws (PMS M3X20mm), 1 pcs of plates (48.3x44x8.8mm) with 2 screws (FMS M3X4mm) |
Connectors
Model No. | Description | |
---|---|---|
M12A-5P-IP68 | Field-installable A-coded screw-in sensor connector, female | |
M12D-4P-IP68 | Field-installable D-coded screw-in sensor connector, male |
White Paper: Optimized Ethernet Redundancy for Inter-Consist NetworksNetwork redundancy is a critical factor in ensuring passenger safety and journey reliability in onboard railway communications for both intra-consist and inter-consist Ethernet networks. In addition, railway operators are looking for ways to more efficiently allocate resources and serve passenger demands. For example, metropolitan rail services may want to run trains with fewer consists during off-peak hours but longer trains with more consists during rush hour. Railway operators can also serve multiple markets and conserve track assets by connecting multiple consists with different destinations into one train if they will travel along the same route for at least part of the journey. This white paper describes how Dynamic Ring Coupling helps railway operators provide seamless onboard Ethernet redundancy with both rapid recovery times and automatic Ethernet switch configuration even when consists are rearranged mid-journey. | |
2015 Railway Application GuideMoxa has provided key communications, data control, and computing infrastructure for dozens of successful major railway projects around the world. Metro, mainline, high speed rail, and conventional rolling stock applications on six continents. This brochure examines some key application scenarios and how Moxa addresses today’s industrial challenges. This brochure covers the following applications:
|