Features and Benefits
• Isolated power inputs with universal 24 to 110 VDC power supply
• Complies with all EN 50155 mandatory test items*
• -40 to 75°C operating temperature range
• Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches), RSTP/STP, and MSTP for network redundancy
*This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here:
www.moxa.com/doc/specs/EN_50155_Compliance.pdf
Introduction
The ToughNet TN-4500A series M12 managed Ethernet switches are designed for railway applications, including rolling stock and wayside installations. The TN series switches use M12 and other circular connectors to ensure tight, robust connections, and guarantee reliable operation against environmental disturbances, such as vibration and shock. The TN-4516A-4GTX series Ethernet switches have 12 Fast Ethernet M12 ports and 4 Gigabit Ethernet ports, and have a wide power input range of 24 to 110 VDC, and a wide operating temperature range of -40 to 75°C. In addition, TN-4516A-4GTX switches are compliant with the mandatory sections of EN 50155, covering operating temperature, power input voltage, surge, ESD, and vibration, making the switches suitable for a variety of industrial applications.
• Technology | |
Standards | IEEE 802.3af for Power-over-Ethernet IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3x for Flow Control IEEE 802.1D-2004 for Spanning Tree Protocol IEEE 802.1w for Rapid STP IEEE 802.1s for Multiple Spanning Tree Protocol IEEE 802.1Q for VLAN Tagging IEEE 802.1p for Class of Service IEEE 802.1X for Authentication IEEE 802.3ad for Port Trunk with LACP |
Protocols | IGMPv1/v2, GMRP, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, DHCP Option 66/67/82, BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, SSH, Syslog, EtherNet/IP, Modbus/TCP, SNMP Inform, LLDP, IEEE 1588 PTP V2, IPv6, NTP Server/Client, TACACS+ |
MIB | MIB-II, Ethernet-like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9 |
Flow Control | IEEE802.3x flow control, back pressure flow control |
• Switch Properties | |
Priority Queues | 4 |
Max. Number of Available VLANs | 64 |
VLAN ID Range | VID 1 to 4094 |
IGMP Groups | 256 |
• Interface | |
Fast Ethernet | Front cabling, M12 connector, 10/100BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection |
Gigabit Ethernet | Front cabling, M12 X-coded 8-pin connector, 10/100/1000BaseT(X) auto negotiation speed, F/H duplex mode, auto MDI/MDI-X connection |
Console Port | M12 A-coding 5-pin male connector |
System LED Indicators | PWR1, PWR2, FAULT, MSTR/HEAD, CPLR/TAIL |
Port LED Indicators | 10/100M (Fast Ethernet port) |
Alarm Contact | 2 relay outputs in one M12 A-coding 5-pin male connector with current carrying capacity of 1 A @ 30 VDC |
• Power Requirements | |
Input Voltage | 24 to 110 VDC (16.8 to 137.5 VDC) |
Input Current | Max. 0.7 A @ 24 VDC |
Overload Current Protection | Present |
Connection | M23 connector |
Reverse Polarity Protection | Present |
• Physical Characteristics | |
Housing | Metal, IP40 protection (optional protective caps available for unused ports) |
Dimensions | 229.8 x 132 x 122.3 mm (9.05 x 5.20 x 4.81 in) |
Weight | TN-4516A-4GTX series: 2550 g |
Installation | Panel mounting kit |
• Environmental Limits | |
Operating Temperature | -40 to 75°C (-40 to 167°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Altitude | Up to 2000 m |
Note: Please contact Moxa if you require products guaranteed to function at higher altitudes. | |
• Standards and Certifications | |
Safety | UL 61010-2-201 (Pending), EN 60950-1 (LVD) |
EMC | EN 55032, EN 55024 |
EMI | CISPR 32, FCC Part 15B Class A |
EMS | IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 |
Rail Traffic | (for panel mounting installations) EN 50155*, EN 50121-4, EN 45545-2 |
*This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here: www.moxa.com/doc/specs/EN_50155_Compliance.pdf | |
Shock | EN 50155, IEC 61373 |
Freefall | IEC 60068-2-31 |
Vibration | EN 50155, IEC 61373 |
Model No. | Description | |
---|---|---|
TN-4516A-4GTX-WV-T | Managed Ethernet switch with 12 10/100BaseT(X) ports, and 4 10/100/1000BaseT(X) ports with M12 connectors, dual redundant power inputs (24 – 110 VDC), -40 to 75°C operating temperature | |
TN-4516A-4GTX-WV-CT-T | Managed Ethernet switch with 12 10/100BaseT(X) ports, and 4 10/100/1000BaseT(X) ports with M12 connectors, dual redundant power inputs (24 – 110 VDC), -40 to 75°C operating temperature, conformal coating model | |
TN-4516A-4GTXBP-WV-T | Managed Ethernet switch with 12 10/100BaseT(X) ports, and 4 10/100/1000BaseT(X) ports with M12 connectors, 4 Gigabit ports with bypass relay function support, dual redundant power inputs (24 – 110 VDC), -40 to 75°C operating temperature | |
TN-4516A-4GTXBP-WV-CT-T | Managed Ethernet switch with 12 10/100BaseT(X) ports, and 4 10/100/1000BaseT(X) ports with M12 connectors, 4 Gigabit ports with bypass relay function support, dual redundant power inputs (24 – 110 VDC), -40 to 75°C operating temperature, conformal coating model |
Power Cords
Model No. | Description | |
---|---|---|
CBL-M23(FF6P)/Open-BK-100 IP67 | M23 Power Cords | |
CBL-M12(FF5P)/Open-100 IP67 | 1-meter A-coded M12-to-5-pin power cable, 5-pin female M12 connector, IP67-rated |
Connection Cables
Model No. | Description | |
---|---|---|
CBL-M12D(MM4P)/RJ45-100 IP67 | 1-meter D-coded M12-to-RJ45 Cat-5C UTP Ethernet cable, 4-pin male M12 connector, IP67-rated |
Wireless Connector Cap
Model No. | Description | |
---|---|---|
A-CAP-M12M-M | Metal cap for M12 male connector | |
A-CAP-M12F-M | Metal Cap for M12 Female Connector |
Connectors
Model No. | Description | |
---|---|---|
M12A-5P-IP68 | Field-installable A-coded screw-in sensor connector, female | |
M12D-4P-IP68 | Field-installable D-coded screw-in sensor connector, male |
White Paper: Optimized Ethernet Redundancy for Inter-Consist NetworksNetwork redundancy is a critical factor in ensuring passenger safety and journey reliability in onboard railway communications for both intra-consist and inter-consist Ethernet networks. In addition, railway operators are looking for ways to more efficiently allocate resources and serve passenger demands. For example, metropolitan rail services may want to run trains with fewer consists during off-peak hours but longer trains with more consists during rush hour. Railway operators can also serve multiple markets and conserve track assets by connecting multiple consists with different destinations into one train if they will travel along the same route for at least part of the journey. This white paper describes how Dynamic Ring Coupling helps railway operators provide seamless onboard Ethernet redundancy with both rapid recovery times and automatic Ethernet switch configuration even when consists are rearranged mid-journey. | |
2015 Railway Application GuideMoxa has provided key communications, data control, and computing infrastructure for dozens of successful major railway projects around the world. Metro, mainline, high speed rail, and conventional rolling stock applications on six continents. This brochure examines some key application scenarios and how Moxa addresses today’s industrial challenges. This brochure covers the following applications:
|
tn-4516a-4gtx-series-safenergy-i-din-moxa-ti-vit-nam