TAP-6226 Series

Railway trackside 802.11a/b/g IP68 wireless unit

TAP 6226 Series

Note: The TAP-6226 series is being phased out. The phase out period is July 1, 2017, to December 1, 2017. Last buy orders must be received before December 1, 2017. Please contact your Moxa sales representative if you have further questions.

Features & Benefits

  • 2 dual-band radios, IEEE 802.11a/b/g compliant
  • Railway approved IP68 housing
  • Controller-based Turbo Roaming
  • 2 fiber SFP ports and 4 PoE ports with M12 LAN connectors
  • High transmission power for extended reach
  • Complies with a portion of EN 50155 specifications
  • -40 to 75°C operating temperature range

Introduction 

The TAP-6226 trackside wireless unit is designed for board to ground wireless communication. It is a highly compact and rugged wireless unit that integrates two access points, a managed fiber switch, and a wide-range AC/DC power supply, all into one box. The IP68 housing allows the unit to withstand the harshest weather, and M12 connectors make the unit shock and vibration proof. The TAP-6226 supports advanced controller-based Turbo Roaming technology for applications such as Communication-Based Train Control (CBTC). The unit can
supply power to up to 4 PoE devices while providing reliable LAN communication with Moxa’s Turbo Chain technology.

Advanced Mobility and Reliability

• Controller-based L3 Turbo Roaming
• Mobile IP support
• 2 dual-band radios: 2.4 GHz and 5.1 to 5.9 GHz
• Turbo Chain support
• WPA/WPA2 and 802.11i support
• IEEE 802.1X/RADIUS support

Built for Transportation Applications

• Isolated 110 to 220 VDC/VAC power input
• High transmission power, 400 mW
• Supplies power through 4 PoE ports
• 2 fiber SFP ports for backbone installation
• Wide temperature (-40 to 75°C) and IP68 housing

• WLAN Interface
StandardsIEEE 802.11a/b/g for Wireless LAN
IEEE 802.11i for Wireless Security
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseTX
IEEE 802.3af for Power-over-Ethernet
IEEE 802.1D for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1p for Class of Service
IEEE 802.1Q for VLAN
Spread Spectrum and Modulation (typical)• DSSS with DBPSK, DQPSK, CCK
• OFDM with BPSK, QPSK, 16QAM, 64QAM
• 802.11b: CCK @ 11/5.5 Mbps, DQPSK @ 2 Mbps, DBPSK @ 1 Mbps
• 802.11a/g: 64QAM @ 54/48 Mbps, 16QAM @ 36/24 Mbps, QPSK @ 18/12 Mbps, BPSK @ 9/6 Mbps
Operating Channels (central frequency)US:
2.412 to 2.462 GHz (802.11a/b/g, 11 channels)
5.18 to 5.24 GHz (802.11a, 4 channels)
5.26 to 5.825 GHz (optional)
EU:
2.412 to 2.472 GHz (802.11abg, 13 channels)
5.18 to 5.24 GHz (802.11a, 4 channels)
5.26 to 5.825 GHz (optional) 
*Special frequency bands (such as 5.9 GHz) is available for customization.
Security• SSID broadcast enable/disable
• Firewall for MAC/IP/Protocol/Port-based filtering
• 64-bit and 128-bit WEP encryption, WPA/WPA2-Personal and Enterprise (IEEE 802.1X/RADIUS, TKIP, and AES)
Transmission Rates802.11b: 1, 2, 5.5, 11 Mbps
802.11a/g: 6, 9, 12, 18, 24, 36, 48, 54 Mbps
TX Transmit Power802.11b:
Typ. 26±1.5 dBm @ 1 to 11 Mbps
802.11g:
Typ. 26±1.5 dBm @ 6 to 24 Mbps, Typ. 25±1.5 dBm @ 36 Mbps, Typ. 24±1.5 dBm @ 48 Mbps, Typ. 23±1.5 dBm @ 54 Mbps
802.11a:
Typ. 26±1.5 dBm @ 6 to Mbps, Typ. 25±1.5 dBm @ 36Mbps, Typ. 24±1.5 dBm @ 48 Mbps, Typ. 23±1.5 dBm @ 54 Mbps
RX Sensitivity802.11b:
-97 dBm @ 1 Mbps, -94 dBm @ 2 Mbps, -92 dBm @ 5.5 Mbps, -90 dBm @ 11 Mbps
802.11g:
-93 dBm @ 6 Mbps, -91 dBm @ 9 Mbps, -90 dBm @ 12 Mbps, -88 dBm @ 18 Mbps, -84 dBm @ 24 Mbps, -80 dBm @ 36 Mbps, -76 dBm @ 48 Mbps, -74 dBm @ 54 Mbps
802.11a:
-90 dBm @ 6 Mbps, -89 dBm @ 9 Mbps, -89 dBm @ 12 Mbps, -85 dBm @ 18 Mbps, -83 dBm @ 24 Mbps, -79 dBm @ 36 Mbps, -75 dBm @ 48 Mbps, -74 dBm @ 54 Mbps
• Protocol Support
General ProtocolsProxy ARP, DNS, HTTP, HTTPS, IP, ICMP, SNTP, TCP, UDP, RADIUS, SNMP v1/v2/v3, PPPoE, DHCP, STP/RSTP
• Interface
Connector for External AntennasN-type (female)
Fiber Ports2, 100BaseSFP slot
Console PortM12 A-coded 5-pin male connector
LED IndicatorsPWR1, PWR2, PoE1-4, FAULT, STATE, HEAD, TAIL, LAN1-6, WLAN1, WLAN2
Fast Ethernet ports4, side cabling, M12 D-coded 4-pin female connector, 10/100BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection, 802.1af PoE power budget
Fiber Module100Base multi-mode 1300 nm wavelength with LC connector for 4 km transmission (50/125 µm or 62.5/125 µm 800 MHz-km @ 1300 nm wavelength) 
• Physical Characteristics
HousingMetal, IP68 protection
Weight9.7 kg (21.38 lb)
Dimensions324 x 279 x 156 mm (12.76 x 10.98 x 6.14 in)
InstallationWall mounting
• Environmental Limits
Operating Temperature-40 to 75°C (-40 to 167°F)
Storage Temperature-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5% to 95% (non-condensing)
• Power Requirements
Input Voltage110/220 VDC/VAC
Input Current0.68 A @ 110 VDC/VAC
ConnectorM23
Power Consumption74.8 W (max., with PoE ports fully loaded), 15 W (without PoE)
Reverse Polarity ProtectionPresent
Overload Current ProtectionPresent
• Standards and Certifications
SafetyUL 60950-1, EN 60950-1 (CB)
EMCEN 55032/24, EN 61000-6-2/6-4
EMICISPR 32, FCC Part 15B Class A
EMSIEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8
RadioEN 301 489-1/17, EN 300 328, EN 301 893, FCC ID SLE-WAPA004
Rail TrafficEN 50155*, EN45545-2, EN 50121-4 
*Complies with a portion of EN 50155 specifications.
• MTBF (mean time between failures)
Time382,735 hrs
StandardTelcordia SR332

Available Models

 Model No.Description
TAP-6226-TC-US-TRugged trackside wireless access point, US band
TAP-6226-TC-EU-TRugged trackside wireless access point, EU band

Optional Accessories

Wireless Antenna Cable

 Model No.Description
CRF-N0429N-3MN-type (male) to N-type (male), CFD400 cable, 3 m
A-CRF-NMNM-LL4-300N-type (male) to N-type (male), LMR-400 Lite cable, 3 m
A-CRF-NMNM-LL4-600N-type (male) to N-type (male), LMR-400 Lite cable, 6 m
A-CRF-NMNM-LL4-900N-type (male) to N-type (male), LMR-400 Lite cable, 9 m

Wireless Terminating Resistor

 Model No.Description
A-TRM-50-NMTermination resistor, 50 ohms, N-type male

Surge Arrestor

 Model No.Description
A-SA-NFNF-01Surge arrestor, N-type (female) to N-type (female)
A-SA-NMNF-01Surge arrester, N-type (female) to N-type (male)

Power Cords

 Model No.Description
CBL-M23(FF6P)/Open-BK-100 IP67M23 Power Cords

Wireless LAN Antennas

 Model No.Description
ANT-WSB-ANF-092.4 GHz,omni-directional antenna, 9 dBi, N-type (female)
ANT-WSB-PNF-122.4GHz, Directional/Panel antenna, 12dBi, N-type (female) connector
ANT-WSB-PNF-182.4 GHz, panel antenna, 18 dBi, N-type (female)
ANT-WDB-ANM-05022.4/5 GHz, dual-band omni-directional antenna, 5/2 dBi, N-type (male)
ANT-WDB-ANF-06092.4/5 GHz, dual-band omni-directional antenna, 6/9 dBi, N-type (female)
ANT-WDB-PNF-15182.4/5 GHz, dual-band panel antenna, 15/18 dBi, N-type (female)
ANT-WDB-ANF-0407Dual-band omni-directional antenna: 4 dB at 2.4 GHz and 7 dB at 5 GHz
ANT-WSB5-ANF-125 GHz, omni-directional antenna, 12 dBi, N-type (female)
ANT-WSB5-PNF-18Directional panel antenna: 18 dBi at 5 GHz
ANT-WDB-ANM-04072.4/5 GHz, dual-band omni-directional antenna, 4/7 dBi, N-type (male)
ANT-WDB-ANM-06092.4/5 GHz, dual-band omni-directional antenna, 6/9 dBi, N-type (male)

Moxa WLAN Calculator

White Paper: The Four Most Useful Technologies for Train-to-Ground Communications 

Wireless networks are easier to deploy than wired networks, but they can only be used for demanding industrial applications if they meet high reliability and bandwidth requirements. Today, however, wireless technologies are now mature enough to support critical industrial systems and intense applications such as video-over-wireless.This guidebook provide greater insight into the benefits Moxa can offer customers who would like to implement seamless video transmission over high bandwidth wireless networks. 

backtotop
tap-6226-series-safenergy-i-din-moxa-ti-vit-nam