OnCell 5004-HSPA/OnCell 5104-HSPA

Industrial five-band GSM/GPRS/EDGE/UMTS/HSPA cellular routers

router-cong-nghiep-five-band-4-cong-ethernet

Features and Benefits  

  • Five band UMTS/HSPA 800/850/AWS/1900/2100 MHz
  • Quad-band GSM/GPRS/EDGE 850/900/1800/1900 MHz
  • Cellular WAN and Ethernet WAN backup mechanism for a complete path redundancy
  • Primary and secondary power inputs for power source redundancy
  • Cellular link redundancy with dual-SIM GuaranLink support
  • DIN-rail housing and wall-mountable housing
  • Connect to 4 10/100BaseT(X) devices over an integrated VPN
  • 2 digital inputs and 1 relay output (OnCell 5104-HSPA only)
  • Centralize private IP management with OnCell Central Manager

Introduction 

The OnCell 5004/5104-HSPA series are high-performance industrial grade cellular routers that allow up to 4 Ethernet-based devices to simultaneously use a single cellular data account for primary or backup network connectivity to remote sites and devices. Both products provide the functionality of a cellular router, firewall, and switch in one device, and to ensure zero data loss and on-demand cellular communication, the OnCell 5004/5104-HSPA are integrated with the GuaranLink function. The difference between the OnCell 5004-HSPA and OnCell 5104-HSPA is that the OnCell 5104-HSPA comes with a built-in relay output that can be configured to indicate the priority of events when notifying or warning engineers in the field, and the two digital inputs allow you to connect basic I/O devices, such as sensors, to the cellular network. The OnCell 5004-HSPA can be placed on a desktop or wall-mounted, whereas the OnCell 5104-HSPA has an IA design and can be attached to a DIN-rail. Both products use 12 to 48 VDC power inputs with a screw-on design for greater reliability, and the Ethernet ports come with 1.5 KV magnetic isolation protection to keep your system safe from unexpected electrical discharges.

• Cellular Interface
StandardsGSM/GPRS/EDGE/UMTS/HSPA
Band Options• Five-band UMTS/HSPA 800/850/AWS/1900/2100 MHz
• Quad-band GSM/GPRS/EDGE 850/900/1800/1900 MHz
HSPA Data Rate14.4 Mbps DL, 5.76 Mbps UL
EDGE Multi-slot ClassClass 12
EDGE Data Rate237 kbps DL, 237 kbps UL
EDGE Terminal Device ClassClass B
GPRS Multi-slot ClassClass 12
GPRS Data Rate85.6 kbps DL, 85.6 kbps UL
GPRS Terminal Device ClassClass B
GPRS Coding SchemesCS1 to CS4
Tx PowerUMTS/HSPA: 0.25 W
EDGE900: 0.5 W
EDGE1800: 0.4 W
GSM1800: 1 W
GSM900: 2 W
• WAN Interface
Number of Ports1
Ethernet10/100 Mbps, RJ45 connector, auto MDI/MDIX
• LAN Interface
Number of Ports4
Ethernet10/100 Mbps, RJ45 connector, auto MDI/MDIX
• Interface
Cellular Antenna Connectors1, SMA (female)
Console PortRS-232 (RJ45)
• I/O Interface (OnCell 5104-HSPA)
Alarm Contact1 relay output with current carrying capacity of 1 A @ 24 VDC
Digital Inputs2 electrically isolated inputs• +13 to +30 V for state “1”
• +3 to -30 V for state “0”
• Software
Network ProtocolsARP, DDNS, DHCP/BOOTP, DNS Relay, HTTP, HTTPS, ICMP, IPSec, PPP, PPPoE, SMTP, SNTP, SSL, TCP/IP, Telnet, UDP
Routing/FirewallNAT, port forwarding, WAN IP filtering, static route
Cellular ConnectivityGuaranLink
AuthenticationLocal username and password
• Management Software
UtilitiesWireless Search Utility
Configuration and Management OptionsSNMP v1/v2c/v3, Web/Telnet/Serial Console, SSH, Remote SMS Control, Auto IP Report
Centralized Device Management, Monitoring and Private IP SolutionOnCell Central Manager
• SIM Interface
Number of SIMs2
SIM Control3 V
• Physical Characteristics
HousingAluminum, providing IP30 protection
WeightOnCell 5004-HSPA: 510 g (1.12 lb)
OnCell 5104-HSPA: 650 g (1.43 lb)
DimensionsOnCell 5004-HSPA: 158 x 103 x 35 mm (6.22 x 4.06 x 1.38 in)
OnCell 5104-HSPA: 51 x 135 x 103 mm (2 x 5.32 x 4.16 in)
• Environmental Limits
Operating TemperatureStandard Models: -30 to 55°C (-22 to 131°F)
Wide Temp. Models: -30 to 70°C (-22 to 158°F)
Storage Temperature-40 to 75°C (-40 to 167°F)
Ambient Relative Humidity5 to 95% (non-condensing)
• Power Requirements
Number of Power InputsOnCell 5004-HSPA: 2 (1 terminal block, 1 power jack)
OnCell 5104-HSPA: 2 (terminal block), redundant dual inputs
Input Voltage12 to 48 VDC
Input CurrentOnCell 5004-HSPA: 0.9 A @ 12 VDC; 0.23 A @ 48 VDC
OnCell 5104-HSPA: 0.95 A @ 12 VDC; 0.25 A @ 48 VDC
Reverse Polarity ProtectionPresent (OnCell 5104-HSPA only)
• Standards and Certifications
SafetyUL 60950-1
EMCEN 55032/24
EMICISPR 32, FCC Part 15B Class A
EMSIEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 1 kV
IEC 61000-4-5 Surge: Power: 1 kV; Signal: 1 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8
RadioFCC Part 22H, FCC Part 24E, EN 301 489-1, EN 301 489-7, EN 301 489-24, EN 301 511, EN 301 908
• MTBF (mean time between failures)
TimeOnCell 5004-HSPA: 441,000 hrs
OnCell 5104-HSPA: 411,000 hrs
StandardTelcordia SR332

Available Models

 Model No.Description
OnCell 5004-HSPA4-port five-band industrial GSM/GPRS/EDGE/UMTS/HSPA router, -30 to 55°C operating temperature
OnCell 5104-HSPA4-port five-band industrial GSM/GPRS/EDGE/UMTS/HSPA router, IA design, -30 to 55°C operating temperature
OnCell 5104-HSPA-T4-port five-band industrial GSM/GPRS/EDGE/UMTS/HSPA router, IA design, -30 to 70°C operating temperature

Optional Accessories

Wireless Antenna Cable

 Model No.Description
CRF-SMA(M)/N(M)-300N-type (male) to SMA (male), CFD200 cable, 3 m

Wireless AP Mounting Kit

 Model No.Description
WK-51-01Wall-mounting kit, 51mm wide

Cellular Antennas

 Model No.Description
ANT-LTE-ANF-04Full-band GSM/GPRS/EDGE/UMTS/HSPA/LTE, 4 dBi, omni-directional IP66 outdoor antenna
ANT-WCDMA-AHSM-04-2.5mFive-band GSM/GPRS/EDGE/UMTS/HSPA, 4 dBi, omni-directional, magnetic base antenna
ANT-WCDMA-ANF-00Five-band GSM/GPRS/EDGE/UMTS/HSPA, 0 dBi, omni-directional, outdoor antenna
ANT-WCDMA-ASM-1.5Five-band GSM/GPRS/EDGE/UMTS/HSPA, 1.5 dBi, omni-directional, rubber duck antenna
ANT-LTEUS-ASM-01GSM/GPRS/EDGE/UMTS/HSPA/LTE, 1 dBi, omni-directional, rubber duck antenna
ANT-LTE-ASM-02GPRS/EDGE/UMTS/HSPA/LTE, 2 dBi, omni-directional, rubber duck antenna

White Paper: Choosing a Cellular Network Management Solution that Works for You

The biggest challenge that industries face today is designing a network infrastructure that can meet the constantly evolving industrial communication needs. Industrial networks are heterogeneous communication platforms that have evolved over time to cater to the multifaceted needs of its users. In addition to providing a core network infrastructure, industrial networks must also support the communication needs of the increasing number of devices that are added to the edge networks each day. In this white paper we look at the role of cellular networks in industrial edge networks and discuss how to choose a good cellular network management solution…more

Success Stories: Industrial Wireless Success Stories

Designed for industrial harsh environments, Moxa’s comprehensive product line of WLAN and cellular solutions have been successfully implemented for various mission-critical industrial applications…more

backtotop
oncell-5004-hspa-oncell-5104-hspa-safenergy-i-din-moxa-ti-vit-nam