Features and Benefits

  • 4-port RS-232/422/485 serial device server

    • Serial QoS for configuring serial data transmission priority

    • 2 kV (DC) isolation protection for each serial port (S8455 only)

    • Adjustable pull high/low resistor for RS-485 ports (S8455 only)

  • Built-in managed Ethernet switch

    • S8455I Fiber: Two fiber Ethernet ports and three Ethernet ports

    • S8455I All Copper: Five Ethernet ports

    • S8458: Four fiber Ethernet ports and four Ethernet ports

  • Ethernet redundancy with Turbo Ring and Turbo Chain (recovery time < 20 ms) or RSTP/STP (IEEE 802.1w/D) supported
  • QoS, IGMP-snooping/GMRP, VLAN, LACP, SNMPv1/v2c/v3, RMON supported
  • Surge protection for serial, power, and Ethernet

Overview

The NPort S8000 series combines an industrial device server with a full-function managed Ethernet switch with 4 RS-232/422/485 serial ports, allowing you to easily install, manage, and maintain the product.
Combining a device server and switch in one product allows you to save space in your cabinet, reduce overall power consumption, and reduce costs, since you will not need to purchase a switch and serial device server separately.

Supports the Full Range of NPort 5000 Series Device Server Functions

The NPort S8000 series supports the complete array of NPort 5000 series device server functions. You can network your existing serial devices by connecting up to 4 serial devices through Ethernet ports, with only basic configuration required. In addition, data transmission between the serial and Ethernet interfaces is bi-directional.

Full-function Managed Ethernet Switch

The NPort S8000 series has a built-in full-function managed Ethernet switch that supports QoS, IGMP-snooping/GMRP, VLAN, Port Trunking, SNMPv1/v2c/v3, and IEEE 802.1X, allowing you to handle virtually any kind of application. Ethernet redundancy, which is used to increase the reliability and availability of your industrial Ethernet network, is provided by Moxa’s Turbo Ring and Turbo Chain technology (recovery time < 20 ms) or RSTP/STP (IEEE 802.1w/D).

Ring Redundancy at the Device Level

Device-level communication networks for industrial automation are very critical since they are used to control and monitor device processes. The reliability of these communications depends on ring redundancy at the device level. which is designed to provide fast network fault detection and reconfiguration in order to support the most demanding control applications. The NPort S8000 series integrates a full function NPort device server with an industrial switch to carry serial and Ethernet devices at the same time. In addition, the NPort S8000 can also achieve ring redundancy with standard STP/RSTP and Moxa’s proprietary Turbo Ring or Turbo Chain 2 redundancy protocols. This all-in-one design can be used to optimize and simplify your device network and enhance reliability.

Rugged Design with Complete Protection 

• General Specifications
• Port Summary
Serial Ports4 RS-232/422/485 ports
Ethernet Switch PortsNPort S8455I all copper: 5 RJ45 copper ports
NPort S8455I fiber: 3 RJ45 copper ports and 2 fiber ports
NPort S8458: 4 RJ45 copper ports and 4 fiber ports
Console Ports1 (8-pin RJ45 connector)
• Physical Characteristics
HousingMetal
WeightNPort S8455I: 578 g (1.27 lb)
NPort S8458: 1,105 g (2.44 lb)
DimensionsNPort S8455I: 73.1 x 134 x 125 mm (2.88 x 5.27 x 4.92 in)
NPort S8458: 93 x 144 x 125 mm (3.66 x 5.64 x 4.92 in)
• Environmental Limits
Operating TemperatureStandard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models:
NPort S8455I-T: -40 to 75°C (-40 to 167°F)
NPort S8458-T: -40 to 85°C (-40 to 185°F)
Storage Temperature-40 to 75°C (-40 to 167°F)
Ambient Relative Humidity5 to 95% (non-condensing)
• Power Requirements
Input Voltage12 to 48 VDC
Input CurrentNPort S8455I: 935 mA @ 12 VDC
NPort S8458: 940 mA @ 12 VDC
• Standards and Certifications
SafetyUL 508, UL 60950-1
EMCEN 55022/24
EMICISPR 22, FCC Part 15B Class A
EMSNPort S8455I:
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV
IEC 61000-4-5 Surge: Power 1 kV (4 kV for all copper models); Signal: 0.25 kV
IEC 61000-4-6 CS: 150 kHz to
Hazardous LocationUL/cUL Class I Division 2 Groups A/B/C/D (S8455I all copper model only)
• Warranty
Warranty Period5 years
DetailsSee www.moxa.com/warranty
• Device Server Specifications
• Serial Interface
Number of Ports4
Serial StandardsRS-232/422/485
ConnectorDB9 male
Serial Line Protection2 kV isolation protection (NPort S8455I only)
RS-485 Data Direction ControlADDC® (Automatic Data Direction Control)
Pull High/Low Resistor for RS-4851 KΩ, 150 KΩ
Terminator for RS-485120 Ω
Console PortDedicated RS-232 console port (8-pin RJ45)
• Serial Communication Parameters
Data Bits5, 6, 7, 8
Stop Bits1, 1.5, 2
ParityNone, Even, Odd, Space, Mark
Flow ControlRTS/CTS and XON/XOFF
Baudrate50 bps to 921.6 Kbps
• Serial Signals
RS-232TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422Tx+, Tx-, Rx+, Rx-, GND
RS-485-4wTx+, Tx-, Rx+, Rx-, GND
RS-485-2wData+, Data-, GND
• Software
Configuration OptionsWeb Console, Telnet Console, Serial Console, Windows Utility
Windows Real COM DriversWindows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded
Fixed TTY DriversSCO Unix, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X
Linux Real TTY DriversLinux 2.4.x, 2.6.x, 3.x
Operation ModesReal COM, TCP Server, TCP Client, UDP, RFC2217
ManagementSNMP MIB-II
• Reliability
Alert ToolsBuilt-in buzzer and RTC (real-time clock)
Automatic Reboot TriggerBuilt-in WDT (watchdog timer)
• MTBF (mean time between failures)
TimeNPort S8455I Single-mode: 286,993 hrs
NPort S8455I Multi-mode: 200, 951 hrs
NPort S8455I All copper: 287,354 hrs
NPort S8458: 163,624 hrs
StandardTelcordia (Bellcore) Standard TR/SR
• Ethernet Switch Specifications
• Ethernet Interface
StandardsIEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for Flow Control
IEEE 802.1D for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1x for Authenti
Network ProtocolsICMP, IPv4, TCP, UDP, ARP, Telnet, DNS, HTTP, SMTP, SNTP, IGMPv1/v2, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, DHCP Option 82, BootP, TFTP, SNTP, SMTP, RARP, GMRP, LACP, RMON
MIBMIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
Flow ControlIEEE 802.3x flow control, back pressure flow control interface
• Switch Properties
Priority Queues4
Max. Number of Available VLANs64
VLAN ID RangeVID 1 to 4094
IGMP Groups256
• Optical Fiber Interface
• Switch Interface
RJ45 Ports10/100BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection
DIP SwitchesTurbo Ring, Master, Coupler, Reserve
Alarm Contact2 relay outputs with current carrying capacity of 1A @ 24 VDC

To request a quote, indicate which items you are interested in below and click “Get a Quote”.

Available Models

Model No.Description
NPort S8455I4 RS-232/422/485 ports, 5 10/100M Ethernet ports, 12 to 48 VDC, 2 kV isolation protection, 0 to 60°C operating temperature
NPort S8455I-T4 RS-232/422/485 ports, 5 10/100M Ethernet ports, 12 to 48 VDC, 2 kV isolation protection, -40 to 75°C operating temperature
NPort S8455I-MM-SC4 RS-232/422/485 ports, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with SC connector, 15 KV ESD, 12-48 VDC, 0 to 60°C
NPort S8455I-SS-SC4 RS-232/422/485 ports, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with SC connector, 15 KV ESD, 12-48 VDC, 0 to 60°C
NPort S8455I-MM-SC-T4 RS-232/422/485 ports, 3 10/100M Ethernet ports, 2 100M multi-mode fiber ports with SC connector, 15 KV ESD, 12-48 VDC, -40 to 75°C
NPort S8455I-SS-SC-T4 RS-232/422/485 ports, 3 10/100M Ethernet ports, 2 100M single-mode fiber ports with SC connector, 15 KV ESD, 12-48 VDC, -40 to 75°C
NPort S8458-4S-SC-T4 RS-232/422/485 ports, 4 10/100M Ethernet ports, 4 100M single-mode fiber ports with SC connector, 12-48 VDC, -40 to 85°C operating temperature

Optional Accessories

 Connectors

Model No.Description
Mini DB9F-to-TBDB9 Female to Terminal Block connector
 Trial Software

Model No.Description
MXviewIndustrial network management software designed for converged automation networks

Appearance

Dimensions

 

 

Pin Assignment

 

 

 

 

 

backtotop