Moxa’s easy-to-use ioSearch software, you can quickly access all of an ioLogik R1200 series device’s status information and settings in a user friendly graphic interface. Furthermore, ioSearch also provides an easy method for updating firmware for all ioLogik R1200 devices over an RS-485 network, so you can even update your firmware remotely. This free and easy-to-use ioSearch softwarewill reduce your maintenance time and labor effort.
Moxa’s ioLogik R1200 lets you set up your communication interface using a simple software utility. When the ioLogik R1200 is on the same RS-485 network, you no longer need to turn hundreds of dials during setup. Instead, simply configure and duplicate each ioLogik R1200’s baudrate and mode through the graphical user interface. This convenient software feature eases the effort of maintenance engineers, and greatly simplifies upgrading traditional device configuration.
With the industry’s first RS-485 serial remote I/O with USB design, Moxa provides an innovative solution for upgrading and configuring RS-485 remote I/O communication devices and firmware. All you need to do is upload the configurations to a USB drive, plug it into the field device, and all the configurations and firmware updates will upload to the field device. This innovative solution allows anyone, even someone with no technical background, to upload a device’s configurations and firmware by USB so you no longer need to bring your computer to the field site to perform routine maintenance.
Moxa’s ioLogik R1200 provides dual RS-485 ports so when one of your RS-485 ports is damaged, you can quickly switch to the other RS-485 port for quick testing or repair. RS-485 remote I/O devices are already considered a low cost technology, but with dual RS-485 ports, Moxa helps you save a little bit more.
With the ioLogik R1200, you can take advantage of our dual RS-485 ports to set up wiring, provide computer redundancy, or backup your network using two computer topologies. For wiring redundancy, when your computer detects that one of the RS-485 connections is not responding, it can quickly switch over to the other RS-485 line to guarantee continuous communication between the field sensor and the central computer. Furthermore, users have the freedom to define the settings. For computer redundancy, the ioLogik R1200 provides system operators with a secure backup when one system goes down.
ioLogik R1212 Specifications | |
• Inputs and Outputs | |
Digital Inputs | 8 channels |
Configurable DIOs (by jumper) | 8 channels |
Isolation | 3k VDC or 2k Vrms |
• Digital Input | |
Sensor Type | Wet Contact (NPN or PNP), Dry Contact |
I/O Mode | DI or Event Counter |
Dry Contact | • On: short to GND • Off: open |
Wet Contact (DI to COM) | • On: 10 to 30 VDC • Off: 0 to 3 VDC |
Common Type | 8 points per COM |
Counter Frequency | 2.5 kHz |
Digital Filtering Time Interval | Software Configurable |
• Digital Output | |
Type | Sink |
I/O Mode | DO or Pulse Output |
Pulse Output Frequency | 5 kHz |
Over-Voltage Protection | 45 VDC |
Over-Current Protection | 2.6 A (4 channels @ 650 mA) |
Over-Temperature Shutdown | 175°C (typical), 150°C (min.) |
Current Rating | 200 mA per channel |
• Power Requirements | |
Input Voltage | 12 to 48 VDC |
Input Current | 187 mA @ 24 VDC |
Common Specifications | |
• Serial | |
Interface | 2 RS-485-2w terminal block ports |
Serial Line Protection | • ESD Protection: 15 kV • Surge Protection: 1 kV • High/Low Resistor for RS-485: 1 kΩ, 150 kΩ |
Parity | None, Even, Odd |
Data Bits | 8 |
Stop Bits | 1, 2 |
Baudrate | 1200 to 921600 bps |
Protocols | Modbus RTU (slave) |
• Physical Characteristics | |
Wiring | I/O cable max. 16 AWG |
Dimensions | 27.8 x 124 x 84 mm (1.09 x 4.88 x 3.31 in) |
Weight | Under 200 g (0.44 lb) |
Mounting | DIN-rail or wall |
• Environmental Limits | |
Operating Temperature | Standard Models: -10 to 75°C (14 to 167°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Shock | IEC 60068-2-27 |
Vibration | IEC 60068-2-6 |
Altitude | Up to 2000 m Note: Please contact Moxa if you require products guaranteed to function properly at higher altitudes. |
• Standards and Certifications | |
Safety | UL 508 |
EMC | EN 55032/24 |
EMI | CISPR 32, FCC Part 15B Class A |
EMS | IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 0.5 kV IEC 61000-4-5 Surge: Power: 2 kV IEC 61000-4-6 CS: 3 V IEC 61000-4-8 |
Green Product | RoHS, CRoHS, WEEE Please check Moxa’s website for the most up-to-date certification status. |
• MTBF (mean time between failures) | |
Time | 1,239,293 hrs |
Standard | Telcordia SR332 |
• Warranty | |
Warranty Period | 5 years (excluding the ioLogik R1214) |
Details | See www.moxa.com/warranty Note: Because of the limited lifetime of power relays, products that use this component are covered by a 2-year warranty. |
Model No. | Description | |
---|---|---|
ioLogik R1212 | RS-485 remote I/O, 8 DIs, 8 DIOs | |
ioLogik R1212 -T | RS-485 remote I/O, 8 DIs, 8 DIOs, -10 to 85°C operating temperature. |
Smart I/O Success Stories
The innovation of Moxa’s data acquisition engineers is reflected in Moxa’s latest I/O products, which are helping companies around the world simplify the management of distributed control systems, and as a result reduce costs and create business growth. In addition, Moxa also provides innovative data acquisition software that helps businesses simplify the process of integrating I/O devices with an existing network. This smart automation software not only helps users gather data faster and more efficiently, but also helps businesses identify, assess, and monitor potential risks.
Download this 16-page Smart I/O Brochure to learn more about:
– The Smarter World Trend
– Moxa’s Innovative Designs
– Moxa’s Easy-to-Use Automation Software
– Success Stories Based on Moxa’s Smart I/O Solutions
– Moxa’s Smart IO Product Selection Guide
Related White Papers
A New Chapter in the Legacy of RS-485 Data Acquisition Devices
This white paper provides insight into the future of RS-485 data acquisition devices, and how Moxa is adding a new chapter to the legacy of RS-485 data acquisition devices.
SNMP I/O Devices Make Monitoring Environmental Conditions Easy
This paper will first explain what SNMP is, why you should use SNMP for environmental monitoring, and then discuss how an SNMP environmental monitoring device will help ease the management and implementation process.
Hardware Informations:
Dimensions (unit = mm)
iologik-r1212-safenergy-i-din-moxa-ti-vit-nam