ICF-1180I Series

Industrial PROFIBUS-to-fiber converters

bo-chuyen-doi-profibus-sang-soi-quang

Features and Benefits

  • Fiber cable test function validates fiber communication
  • Auto baudrate detection and data speed up to 12 Mbps
  • PROFIBUS bus fail prevents corrupted datagram in functioning segment
  • Fiber inverse feature
  • Alarm by relay output
  • 2 kV galvanic isolation protection
  • Dual power inputs for redundancy (Reverse power protection)
  • Extends PROFIBUS transmission distance up to 45 km
  • Wide temperature model available for -40 to 75°C environments
  • Supports Fiber Signal Intensity Diagnosis

Overview

The ICF-1180I series industrial PROFIBUS-to-fiber converters are used to convert PROFIBUS signals from copper to optical fiber. The converters are used to extend serial transmission up to 4 km (multi-mode fiber) or up to 45 km (single-mode fiber). The ICF-1180I
provides 2 kV isolation protection for the PROFIBUS system and dual power inputs to ensure that your PROFIBUS device will perform uninterrupted.

 

Fiber Cable Test Function

Fiber-optic cables are usually deployed for long distance communication. To ensure proper communication across the fiber-optic cables, engineers use fiber sensors. With fiber cable test function through DIP switch adjustments, the ICF-1180I series converters eliminate the need to rely on fiber-optic sensors. This function not only detects fiber communication abnormalities but also validates the format of the received packet. It can also determine which side (Tx or Rx) is causing the problem.

 

PROFIBUS Fail Safe

When the PROFIBUS device malfunctions or the serial interface fails, it will generate electrical noise, resulting in bus failure. Traditional media converters will let the noise signal pass through the fiber and on to the other converter. This will disrupt data transmissions between the two buses and eventually communication ceases across the entire system. When this occurs, the engineer will not be able to easily locate the failed device because the entire PROFIBUS network is down. To avoid this situation, the ICF-1180I was designed to detect and recognize noise signals. If the bus fails on one side, the noise signal will not propagate through the ICF-1180I and affect additional bus segments. In addition, the ICF-1180I will also trigger an alarm notification to the field engineer on the location of the failure.

Fiber Signal Intensity Diagnosis

In some circumstances, you may need to measure the receive level of the fiber optic port with a voltmeter, which can be connected while the device is operating (doing so will not affect data transmission). The measurement can be taken with a voltmeter and read on a PLC that uses floating high impedance analog inputs, which allows you to do the following: 1. Record the incoming optical power for later measurement (e.g., to indicate aging or damage). 2. Carry out a good/bad test (limit value).

• Technology
StandardsIEC 61158-2 for PROFIBUS DP
• Interface
P1 PortST optical fiber
P2 PortPROFIBUS DP (DB9 female)
Relay AlarmOne relay output with current carrying capacity of 2 A @ 30 VDC (Normal open)
LED IndicatorsPWR1, PWR2, Ready, P1 Status, P2 Status
DIP SwitchesDIP 1 to 4: Baudrate setting
DIP 5: Fiber link monitor
DIP 6: Fiber inverse function
DIP 7: Reserved
DIP 8: Fiber cable test function
• PROFIBUS Communication
Data Rate9.6, 19.2, 45.45, 93.75, 187.5, 500, 1500, 3000, 6000, and 12000 kbps
Auto BaudrateYes
Isolation Protection2 kV
• Optical Fiber Side
Point-to-Point Transmission
• Physical Characteristics
HousingMetal
MountingDIN-Rail mounting, wall mounting (with optional kit)
Dimensions30.3 x 115 x 70 mm (1.19 x 4.53 x 2.76 in)
Weight180 g (0.39 lb)
• Environmental Limits
Operating TemperatureStandard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature-40 to 75°C (-40 to 167°F)
Ambient Relative Humidity5 to 95% (non-condensing)
• Power Requirements
Rated Voltage12 to 48 VDC
Rated Current143 mA @ 24 V
ConnectorTerminal Block
Power Line ProtectionLevel 3 (2 kV) Surge Protection
Overcurrent Protection1.1 A
• Standards and Certifications
SafetyUL 508
Hazardous LocationUL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2 EEx nC IIC, IECEx
EMCEN 55032/24
EMICISPR 32, FCC Part 15B Class A
EMSEN 61000-4-2 (ESD): Contact: 6 kV; Air: 8 kV
EN 61000-4-3 (RS): 80 MHz to 1 GHz: 10 V/m
EN 61000-4-4 (EFT): Power: 2 kV; Signal: 2 kV
EN 61000-4-5 (Surge): Power: 2 kV; Signal: 2 kV
EN 61000-R[-35]C4-6 (CS): 150 kHz to 80 MHz: 10 V/m
EN 61000-4-8 (PFM
Green ProductRoHS, CRoHS, WEEE
FreefallIEC 60068-2-32
• Warranty
Warranty Period5 years
DetailsSee www.moxa.com/warranty

Available Models

Model No.Description
ICF-1180I-M-STPROFIBUS to fiber converter, multi-mode, ST connector, 0 to 60°C
ICF-1180I-S-STPROFIBUS to fiber converter, single-mode, ST connector, 0 to 60°C
ICF-1180I-M-ST-TPROFIBUS to fiber converter, multi-mode, ST connector, -40 to 75°C
ICF-1180I-S-ST-TPROFIBUS to fiber converter, single-mode, ST connector, -40 to 75°C

Dimensions

 

Pin Assignment

backtotop
icf-1180i-series-safenergy-i-din-moxa-ti-vit-nam