EDS-316 Series

16-port unmanaged Ethernet switches

switch-ethernet-unmanaged-16-cong-moxa-eds-316

Features and Benefits  

  • Relay output warning for power failure and port break alarm
  • Broadcast storm protection
  • -40 to 75°C operating temperature range (T models) 

Introduction

The EDS-316 are 16-port Ethernet switches that provide an economical solution for your industrial Ethernet connections. The built-in relay warning function alerts network engineers when power failures or port breaks occur, and the switches are designed for harsh industrial environments, such as in hazardous locations (Class 1 Div. 2 / ATEX Zone 2). The switches comply with FCC, UL, and CE standards, and come in two model types: standard operating temperature range models (0 to 60°C) and wide operating temperature range models (-40 to 75°C). Both models undergo a 100% burn-in test to ensure that they fulfill the special needs of industrial automation control applications. The EDS-316 switches can be installed easily on a DIN-rail or in a distribution box.

• Technology
StandardsIEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for Flow Control
Processing TypeStore and Forward
• Switch Properties
MAC Table SizeEDS-305/308/309: 1K
EDS-316: 4K
Packet Buffer SizeEDS-305: N/A
EDS-308/309: 512 kbit
EDS-316: 1.25 Mbit
• Interface
RJ45 Ports10/100BaseT(X) auto negotiation speed, Full/Half duplex mode, and auto MDI/MDI-X connection
Fiber Ports100BaseFX ports (SC/ST connector)
DIP Switches• Port break alarm mask
• Enable/disable broadcast storm protection (EDS-316)
Alarm Contact1 relay output with current carrying capacity of 1 A @ 24 VDC
• Optical Fiber
Table 
• Power Requirements
Input VoltageEDS-305/308: 24 VDC, redundant dual inputs
EDS-309: 24 VDC, redundant dual inputs
EDS-316: 12/24/48 VDC, redundant dual inputs
Operating VoltageEDS-305/308: 12 to 48 VDC
EDS-309: 12 to 45 VDC
EDS-316: 9.6 to 60 VDC
Input CurrentEDS-305: 0.11 A @ 24 V
EDS-305-M/S: 0.13 A @ 24 V
EDS-308: 0.11 A @ 24 V
EDS-308-M/S: 0.17 A @ 24 V
EDS-308-MM/SS: 0.19 A @ 24 V
EDS-309-3M: 0.26 A @ 24 V
EDS-316: 0.24 A @ 24 V
EDS-316-M/S/MM/SS/MS: 0.31 A @ 24 V
Overload Current ProtectionEDS-305, EDS-305-M, EDS-305-S, EDS-308: 1.1 A
EDS-308-M/S/MM/SS, EDS-309 Series: 1.6 A
EDS-316 Series: 2.5 A
Connection1 removable 6-pin terminal block
Reverse Polarity ProtectionSupported
• Physical Characteristics
HousingMetal
IP RatingIP30 protection
DimensionsEDS-305/308/309 Series:
53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
EDS-316 Series:
80.1 x 135 x 105 mm (3.15 x 5.31 x 4.13 in)
WeightEDS-305/308/309 Series: 790 g (1.75 lb)
EDS-316 Series: 1140 g (2.52 lb)
InstallationDIN-rail mounting, wall mounting (with optional kit)
• Environmental Limits
Operating TemperatureStandard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)
• Standards and Certifications
SafetyEDS-305 Series: UL 508, UL 60950-1, CSA C22.2 No. 60950-1
EDS-308/309/316 Series: UL 508, UL 60950-1,
CSA C22.2 No. 60950-1, EN 60950-1
Hazardous LocationUL/cUL Class 1 Division 2 Groups A/B/C/D, ATEX Zone 2 Ex nA nC IIC T4 Gc
EMCEN 55032/24
EMICISPR 32, FCC Part 15B Class A
EMSIEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz, 3 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV
IEC 61000-4-6 CS: 3 V (EDS-309/316: 10 V)
IEC 61000-4-8
MarineDNV, GL
ShockIEC 60068-2-27
FreefallIEC 60068-2-32
VibrationIEC 60068-2-6
NotePlease check Moxa’s website for the most up-to-date certification status.
• MTBF (mean time between failures)
TimeEDS-305 Series: 422,000 hrs
EDS-308 Series: 255,000 hrs
EDS-309 Series: 396,000 hrs
EDS-316 Series: 257,000 hrs
StandardMIL-HDBK-217F, GB 25°C

Available Models

 Model No.Description
EDS-316Unmanaged Ethernet switch with 16 10/100BaseT(X) ports, 0 to 60°C operating temperature
EDS-316-MM-SCUnmanaged Ethernet switch with 14 10/100BaseT(X) ports, and 2 100BaseFX multi-mode ports with SC connectors, 0 to 60°C operating temperature
EDS-316-MM-SC-TUnmanaged Ethernet switch with 14 10/100BaseT(X) ports, and 2 100BaseFX multi-mode ports with SC connectors, -40 to 75°C operating temperature
EDS-316-MM-STUnmanaged Ethernet switch with 14 10/100BaseT(X) ports, and 2 100BaseFX multi-mode ports with ST connectors, 0 to 60°C operating temperature
EDS-316-MM-ST-TUnmanaged Ethernet switch with 14 10/100BaseT(X) ports, and 2 100BaseFX multi-mode ports with ST connectors, -40 to 75°C operating temperature
EDS-316-M-SCUnmanaged Ethernet switch with 15 10/100BaseT(X) ports, and 1 100BaseFX multi-mode port with SC connector, 0 to 60°C operating temperature
EDS-316-M-SC-TUnmanaged Ethernet switch with 15 10/100BaseT(X) ports, and 1 100BaseFX multi-mode port with SC connector, -40 to 75°C operating temperature
EDS-316-MS-SCUnmanaged Ethernet switch with 14 10/100BaseT(X) ports, 1 100BaseFX multi-mode port with SC connector, and 1 100BaseFX single-mode port with SC connector, 0 to 60°C operating temperature
EDS-316-MS-SC-80Unmanaged Ethernet switch with 14 10/100BaseT(X) ports, 1 100BaseFX multi-mode port with SC connector, and 1 100BaseFX single-mode port with SC connector for 80 km transmission, 0 to 60°C operating temperature
EDS-316-MS-SC-TUnmanaged Ethernet switch with 14 10/100BaseT(X) ports, 1 100BaseFX multi-mode port with SC connector, and 1 100BaseFX single-mode port with SC connector, -40 to 75°C operating temperature
EDS-316-M-STUnmanaged Ethernet switch with 15 10/100BaseT(X) ports, and 1 100BaseFX multi-mode port with ST connector, 0 to 60°C operating temperature
EDS-316-M-ST-TUnmanaged Ethernet switch with 15 10/100BaseT(X) ports, and 1 100BaseFX multi-mode port with ST connector, -40 to 75°C operating temperature
EDS-316-S-SCUnmanaged Ethernet switch with 15 10/100BaseT(X) ports, and 1 100BaseFX single-mode port with SC connector, 0 to 60°C operating temperature
EDS-316-S-SC-80Unmanaged Ethernet switch with 15 10/100BaseT(X) ports, and 1 100BaseFX single-mode port with SC connector for 80 km transmission, 0 to 60°C operating temperature
EDS-316-S-SC-TUnmanaged Ethernet switch with 15 10/100BaseT(X) ports, and 1 100BaseFX single-mode port with SC connector, -40 to 75°C operating temperature
EDS-316-SS-SCUnmanaged Ethernet switch with 14 10/100BaseT(X) ports, and 2 100BaseFX single-mode ports with SC connectors, 0 to 60°C operating temperature
EDS-316-SS-SC-40/80Unmanaged Ethernet switch with 14 10/100BaseT(X) ports, 1 100BaseFX single-mode port with SC connector for 40 km transmission, and 1 100BaseFX single-mode port with SC connector for 80 km transmission, 0 to 60°C operating temperature
EDS-316-SS-SC-80Unmanaged Ethernet switch with 14 10/100BaseT(X) ports, and 2 100BaseFX single-mode ports with SC connectors for 80 km transmission, 0 to 60°C operating temperature
EDS-316-SS-SC-TUnmanaged Ethernet switch with 14 10/100BaseT(X) ports, and 2 100BaseFX single-mode ports with SC connectors, -40 to 75°C operating temperature
EDS-316-TUnmanaged Ethernet switch with 16 10/100BaseT(X) ports, -40 to 75°C operating temperature

Optional Accessories

DIN Rail Power Supplies

 Model No.Description
DR-452445W/2A DIN-rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input, -10 to 50°C operating temperature
MDR-60-2460W/2.5A DIN-Rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input, -20 to 70°C operating temperature
MDR-40-2440W/1.7A DIN-Rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input , -20 to 70°C operating temperature
DR-75-2475W/3.2A DIN-rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input, -10 to 60°C operating temperature
DR-120-24120W/5A DIN-rail 24 VDC power supply with universal 88 to 132 VAC or 176 to 264 VAC input by switch, or 248-370 VDC , -10 to 60°C operating temperature

FAQ: Is Your Network Infrastructure Ready for the IIoT?

The Industrial Internet of Things (IIoT) trend aims to improve efficiency and productivity by connecting different devices together as well as collecting and analyzing large volumes of data to offer accurate information. However, before reaping the benefits of the IIoT, users need to ensure that the correct infrastructure is in place. To make sure your network is ready for the IIoT, check out five of the most frequently mentioned questions.

FAQ_cover
2015 Industrial Ethernet Solutions Brochure

Build SMART Connectivity to Boost Your Industrial IoT Opportunities

The Industrial Internet of Things is evolving to achieve all kinds of information automation. Staying ahead of the curve leads to increased productivity, which crucially depends on high efficiency and availability of network connectivity. Moxa’s comprehensive product portfolio goes beyond meeting stringent industrial Ethernet standards, bringing vertical expertise to around-the-clock Industrial IoT operations around the world.

Check out this 24-page IES Brochure to get detailed information of the following products and solutions:
– Automation-Friendly Network Management Suite
– NAT/VPN/Firewall Secure Routers
– Industrial Ethernet Switches
– Industrial Wireless Connectivity
– Industrial Ethernet Gateways
– Field Networking and Automation Solutions

Download IES 2015 Brochure!

backtotop
eds-316-series-safenergy-i-din-moxa-ti-vit-nam