The CI-132 series ISA boards come with 2 independent RS-422/485 serial ports for connecting data acquisition equipment and other serial devices to a PC. Connect your devices over longer distances—up to 1.2 km (4000 ft)—and ensure greater reliability in industrial environments with on-board surge protection and electrical isolation (available with some models). Enjoy greater versatility by using point-to-point full duplex connections, or set up a half duplex RS-485 multi-drop network.
• Hardware | |
Comm. Controller | 16C550C or compatible x 2 |
Bus | 16-bit ISA |
Connectors | DB9 male x 2 |
• Serial Interface | |
Number of Ports | 2 |
Serial Standards | RS-422/485 |
Max. No. of Boards per PC | 4 |
• Serial Line Protection | |
ESD Protection | 25 kV on the board (CI-132IS only) |
Electrical Isolation | 2 kV (CI-132I/IS only) |
• Performance | |
Baudrate | 50 bps to 921.6 kbps |
Built-in Termination Resistor | 120 ohm (enabled by jumper for RS-485-2w) |
• Serial Communication Parameters | |
Data Bits | 5, 6, 7, 8 |
Stop Bits | 1, 1.5, 2 |
Parity | None, Even, Odd, Space, Mark |
I/O Address | 0x0000-0xFFFF (default = 0x180) |
IRQ | 2 (9), 3, 4, 5, 7, 10 (default), 11, 12, 15 |
• Serial Signals | |
RS-422 | TxD+(B), TxD-(A), RxD+(B), RxD-(A), RTS+(B), RTS-(A), CTS+(B), CTS-(A), GND |
RS-485-2w | Data+(B), Data-(A), GND |
RS-485 Data Control | ADDC® (automatic data direction control), or by RTS |
• Physical Characteristics | |
Dimensions | CI-132: 75 x 157 mm (2.95 x 6.18 in) CI-132I/IS: 105 x 157 mm (4.13 x 6.18 in) |
• Driver Support | |
Windows | Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1 (x86/x64), Windows 2008 R2/2012/2012 R2 (x64), DOS, Windows Embedded CE 5.0/6.0, Windows XP Embedded |
Linux | Linux 2.4.x, 2.6.x, 3.x |
Unix-like Systems | QNX 6, SCO OpenServer, UnixWare 7, Solaris 10, FreeBSD |
Note: Please refer to Moxa’s website for the latest driver support information. | |
• Environmental Limits | |
Operating Temperature | 0 to 55°C (32 to 131°F) |
Storage Temperature | -20 to 85°C (-4 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
• Standards and Certifications | |
EMC | EN 55032/24 |
EMI | CISPR 32, FCC Part 15B Class B |
EMS | IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Signal: 2 kV |
• MTBF (mean time between failures) | |
Time | 441,015 hrs |
Standard | Telcordia (Bellcore) TR/SR |
• Power Requirements | |
Input Current | CI-132: 240 mA @ 5 VDC CI-132I/IS: 620 mA @ 5 VDC |
• Warranty | |
Warranty Period | 5 years |
Details | See www.moxa.com/warranty |
Model No. | Description | |
---|---|---|
CI-132 | 2-port RS-422/485 board | |
CI-132I | 2-port RS-422/485 board with optical isolation | |
CI-132IS | 2-port RS-422/485 board with optical isolation and surge protection |
ci-132-series-safenergy-i-din-moxa-ti-vit-nam