Features and Benefits

  • PROFINET enabled by default
  • PROFINET I/O parameters, I/O cyclic data, DCP, DHCP, fully compatible with PROFINET Real-Time
  • PROFINET GSD file, SIMATIC STEP 7 device icons are included
  • Port mirroring, QoS, IEEE 802.1Q VLAN, and port-based VLAN supported

Introduction

The EDS-405A/408A-PN are 5 and 8-port managed Ethernet switches with PROFINET enabled. With embedded PROFINET, the PN switches can be easily integrated into the Simatic Step 7 engineering tool. It is more convenient for automation engineers to configure through Step 7 and monitor with automation HMIs. The EDS-405A/408A-PN switches with fast booting, Turbo Ring and Turbo Chain fast-recovery technology, can optimize PROFINET network performance. Moxa’s PROFINET switches also support a variety of useful management functions, such as IGMP snooping, IEEE 802.1Q VLAN, QoS, port mirroring, SNMP, bandwidth management, and warning by email or relay.

• Technology
StandardsIEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
IEEE 802.3x for Flow Control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1p for Class of Service
IEEE 802.1Q for VLAN Tagging
ProtocolsIGMPv1/v2, GMRP, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, TFTP, SNTP, SMTP, RARP, RMON, HTTP, Telnet, Syslog, DHCP Option 66/67/82, BootP, LLDP, PROFINET, EtherNet/IP, Modbus/TCP, IPv6, NTP Server/Client
MIBMIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
Flow ControlIEEE 802.3x flow control, back pressure flow control
• Switch Properties
MAC Table Size2 K (EDS-405A-PN), 8 K (EDS-408A-PN)
Packet Buffer Size1 Mbit
• Interface
RJ45 Ports10/100BaseT(X) auto negotiation speed, Full/Half duplex mode, and auto MDI/MDI-X connection
Console PortRS-232 (RJ45 connector)
DIP SwitchesTurbo Ring, Master, Coupler, Reserve
LED IndicatorsPWR1, PWR2, FAULT, MSTR/HEAD, CPLR/TAIL, 10/100M
Alarm Contact1 relay output with current carrying capacity of 1 A @ 24 VDC
• Power Requirements
Input Voltage24 VDC (12 to 45 VDC), redundant dual inputs
Input CurrentEDS-405A-PN: 0.24 A @ 24 V
EDS-408A-PN: 0.26 A @ 24 V
Overload Current ProtectionPresent
Connection1 removable 6-contact terminal block
Reverse Polarity ProtectionPresent
• Physical Characteristics
HousingMetal, IP30 protection
Dimensions53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
Packing Size19.2 x 16.8 x 9.3 cm
Weight650 g
Packing WeightEDS-405A-PN series: 1140 g
EDS-408A-PN series: 1220 g
InstallationDIN-rail mounting, wall mounting (with optional kit)
• Environmental Limits
Operating TemperatureStandard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)
• Standards and Certifications
SafetyUL 508, UL 60950-1, CSA C22.2 No. 60950-1, EN 60950-1**
Hazardous LocationUL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2 Ex nC IIC
EMIFCC Part 15 Subpart B Class A, EN 55022 Class A
EMSEN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 3, EN 61000-4-5 (Surge) Level 3,
EN 61000-4-6 (CS) Level 3, EN 61000-4-8
Traffic ControlNEMA TS2
Rail TrafficEN 50121-4*
MarineDNV, GL
ShockIEC 60068-2-27
FreefallIEC 60068-2-32
VibrationIEC 60068-2-6
• MTBF (mean time between failures)
TimeEDS-405A-PN Series: 392,000 hrs
EDS-408A-PN Series: 363,000 hrs
StandardTelcordia (Bellcore), GB

Available Models

 Model No.Description
EDS-408A-PNEntry-level managed Ethernet switch with 8 10/100BaseT(X) ports, 0 to 60°C operating temperature, PROFINET enabled
EDS-408A-PN-TEntry-level managed Ethernet switch with 8 10/100BaseT(X) ports, -40 to 75°C operating temperature, PROFINET enabled
EDS-405A-PNEntry-level managed Ethernet switch with 5 0/100BaseT(X) ports, 0 to 60°C operating temperature, PROFINET enabled
EDS-405A-PN-TEntry-level managed Ethernet switch with 5 10/100BaseT(X) ports, -40 to 75°C operating temperature, PROFINET enabled

Optional Accessories

Category

 Model No.Description
EDS-SNMP OPC Server ProOPC server for integrating SNMP devices into HMI/SCADA systems

DIN Rail Power Supplies

 Model No.Description
DR-452445W/2A DIN-rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input, -10 to 50°C operating temperature
MDR-60-2460W/2.5A DIN-Rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input, -20 to 70°C operating temperature
DR-75-2475W/3.2A DIN-rail 24 VDC power supply with universal 85 to 264 VAC or 120-370 VDC input, -10 to 60°C operating temperature
DR-120-24120W/5A DIN-rail 24 VDC power supply with universal 88 to 132 VAC or 176 to 264 VAC input by switch, or 248-370 VDC , -10 to 60°C operating temperature

Automatic Backup Configurators

 Model No.Description
Automatic Backup Configurator ABC-01Configuration backup and restoration tool for managed switches and wireless APs/Bridges/Clients

Mounting Kits

 Model No.Description
WK-46Wall Mounting Kit
RK-4U4U-high 19″ rack mounting kit

Trial Software

 Model No.Description
MXconfigIndustrial network configuration tool
MXstudio Industrial Network Management SuiteIndustrial network management suite for installation, operation, maintenance, and diagnostics

Brochure

Optimize Your Network Infrastructure for More Industrial IoT Opportunities

While the Industrial Internet of Things (IIoT) with its wave of innovation ushers in immense opportunities for businesses, it also opens the door to new threats. The underlying network infrastructure, therefore, must overcome this ever-growing number of challenges to sustain truly reliable connectivity. This brochure will introduce how Moxa helps its customers and partners optimize industrial network infrastructure to achieve operational efficiency, availability and reliability in various industrial environments

INI_brochure

White Paper

Optimizing PLC Network Performance and Management

To increase productivity and reduce operating costs, many manufacturers and plant operators have deployed industrial Ethernet to converge remotely isolated fieldbus systems for centralized control and monitoring. In addition to systems interoperability, integration of fieldbus segments and industrial Ethernet networks will require the optimization of PLC network performance and manageability. This paper will discuss how three facets of PLC network optimization can ensure high network availability, simplify network monitoring and configuration, and maximize network flexibility.

 PLC_WP

backtotop
eds-405a-pn-eds-408a-pn-series-safenergy-i-din-moxa-ti-vit-nam