EPM-DK03*: GPS receiver, 2 mini PCIe slots
*Operating Temperature:
w/o wireless module: EN 50155 Class TX
w/ wireless module: EN 50155 Class T1
Moxa’s V2400 series expansion modules, which come with serial ports, CAN ports, wireless and GPS cards, digital input/output channel cards, mini PCI and PCIe modules, a 2-slot mini-PCIe module, and VGA or DVI-I display connectors, can be used with Moxa’s V2426 embedded computers, and give end-users the best flexibility for setting up and expanding a variety of industrial applications.
EPM-3032 Specifications | |
• Serial Interface | |
Serial Standards | 2 RS-232/422/485 ports, software-selectable (DB9 male) |
Isolation | 2 kV digital isolation |
• Serial Communication Parameters | |
Data Bits | 5, 6, 7, 8 |
Stop Bits | 1, 1.5, 2 |
Parity | None, Even, Odd, Space, Mark |
Flow Control | RTS/CTS, XON/XOFF, ADDC® (automatic data direction control) for RS-485 |
Baudrate | 50 bps to 921.6 kbps (non-standard baudrates supported; see user’s manual for details) |
• Serial Signals | |
RS-232 | TxD, RxD, DTR, DSR, RTS, CTS, DCD, GND |
RS-422 | TxD+, TxD-, RxD+, RxD-, GND |
RS-485-4w | TxD+, TxD-, RxD+, RxD-, GND |
RS-485-2w | Data+, Data-, GND |
• Physical Characteristics | |
Weight | 137 g (0.30 lb) |
Dimensions | 104 x 121 x 34 mm (4.09 x 4.76 x 1.34 in) |
• Environmental Limits | |
Operating Temperature | -40 to 70°C (-40 to 158°F), EN 50155 Class TX |
EPM-3112 Specifications | |
• CANbus Communication | |
Interface | 2 optically isolated CAN2.0A/2.0B compliant ports |
CAN Controller | Phillips SJA1000T |
Signals | CAN_H, CAN_L |
Isolation | 2 kV digital isolation |
Speed | 1 Mbps |
Connector Type | DB9 male |
• Physical Characteristics | |
Weight | 127 g (0.28 lb) |
Dimensions | 104 x 121 x 34 mm (4.09 x 4.76 x 1.34 in) |
• Environmental Limits | |
Operating Temperature | -25 to 55°C (-13 to 131°F), EN 50155 Class T1 |
EPM-3438 Specifications | |
• Digital Input | |
Input Channels | 8 |
Input Voltage | 0 to 30 VDC at 25 Hz |
Digital Input Levels for Dry Contacts | • Logic level 0: Close to GND • Logic level 1: Open |
Digital Input Levels for Wet Contacts | • Logic level 0: +3 V max. • Logic level 1: +10 V to +30 V (Source to DI) |
Counter Frequency | 2 kHz (DI0 only) |
Connector Type | 10-pin screw terminal block (8 DI points, DI Source, GND) |
Isolation | 3 kV optical isolation |
• Digital Output | |
Output Channels | 8, sink type, 0 to 30 VDC |
Output Current | Max. 200 mA per channel |
On-state Voltage | 24 VDC nominal, open collector to 30 VDC |
Connector Type | 9-pin screw terminal block (8 DO points, GND) |
Isolation | 3 kV optical isolation |
• Physical Characteristics | |
Weight | 120 g (0.27 lb) |
Dimensions | 104 x 121 x 34 mm (4.09 x 4.76 x 1.34 in) |
• Environmental Limits | |
Operating Temperature | -40 to 70°C (-40 to 158°F), EN 50155 Class TX |
EPM-DK02 Specifications | |
• PCI Express Mini Slot | |
Interface | • Slot 1: PCI-Express V1.0 (one lane) / USB 2.0 • Slot 2: USB 2.0 |
USB 2.0 Bus SIM Card Holder | Reserved for cellular applications |
• Physical Characteristics | |
Weight | 125 g (0.28 g) |
• Environmental Limits | |
Operating Temperature | -40 to 70°C (-40 to 158°F), EN 50155 Class TX |
EPM-DK03 Specifications | |
• PCI Express Mini Slot | |
Interface | • Slot 1: PCI-Express V1.0 (one lane) / USB 2.0 • Slot 2: USB 2.0 |
USB 2.0 Bus SIM Card Holder | Reserved for cellular applications |
• Physical Characteristics | |
Weight | 220 g (0.49 lb) |
Dimensions | 104 x 121 x 34 mm (4.09 x 4.76 x 1.34 in) |
• Environmental Limits | |
Operating Temperature | w/o wireless module: -40 to 70°C (-40 to 158°F), EN 50155 Class TX w/ wireless module: -25 to 55°C (-13 to 131°F), EN 50155 Class T1 |
• GPS Interface | |
Receiver Types | • 50-channel u-blox 6 LEA-6 receiver • GPS L1 C/A code • GALILEO L1 open service (with upgrade) • SBAS: WAAS, EGNOS, MSAS, GAGAN |
Acquisition | • Cold starts: 28 s • Warm starts: 28 s • Aided starts: 1 s • Hot starts: 1 s |
Sensitivity | • Tracking: -160 dBm • Reacquisition: -160 dBm • Cold starts: -147 dBm |
Timing accuracy | • RMS: 30 ns • 99%: <60 ns • Granularity: 21 ns |
Accuracy | • Position: 2.5 m CEP • SBAS: 2.0 m CEP |
Protocols | NMEA, UBX binary, max. update rate: 5 Hz (ROM version ) |
Time Pulse | 0.25 Hz to 1 kHz |
Velocity Accuracy | 0.1 m/s |
Heading Accuracy | 0.5 degrees |
A-GPS | Supports AssistNow Online and AssistNow Offline, OMA SUPL compliant |
Operational Limits | Velocity: 500 m/s (972 knots) |
To request a quote, indicate which items you are interested in below and click “Get a Quote”.
Model No. | Description | |
---|---|---|
EPM-DK02 | 2-slot mini PCIe expansion module, -25 to 55°C operating temperature | |
EPM-DK03 | GPS receiver, 2 mini PCIe slots, -25 to 55°C operating temperature | |
EPM-3032 | 2 isolated RS-232/422/485 ports with DB9 connectors, -40 to 70°C operating temperature | |
EPM-3112 | 2 isolated CAN ports with DB9 connectors, -25 to 55°C operating temperature | |
EPM-3438 | 8+8 DI/DO with 3 KV digital isolation protection, 2 KHz counter, -40 to 70°C operating temperature |
Professional Design Service
Moxa’s customization service for industrial computing products is based on the Professional Design Service (PDS) concept, which aims to provide customers with tailor-made solutions. Industrial applications often have specific requirements, and specialized solutions are often needed. With more than 20 years of experience in the industrial networking and automation field, Moxa can offer professional, customized products and services that are ideal for your own industrial applications.
Customer Benefits
• Comprehensive consideration of platform system design gives optimal solutions, and guarantees that proposals address customer needs
• Our sophisticated customization procedures are built on meticulous production and quality control processes
• A full-time technical support team gives customers quick and reliable solutions
v2400-series-expansion-modules-safenergy-i-din-moxa-ti-vit-nam