Time-Domain Reflectometer RIF-9 is designed for determining the distance to a fault in communication and power cables.
Digital impulse reflectometer RIF-9 allows:
Technical Specifications
Parameter | RIF-9 | RIF-7 |
Distance measuring ranges (at V/2=100 m/us),km | 0.1; 0.2; 0.5; 1; 2; 4; 8; 16; 32; 64; 100 | 0.25; 0.5; 1; 2; 4; 8; 16 |
Min. distance to be measured, m | 3 | |
Resolution, m: | ||
− at V/2 = 100 m/us | 0.5 | 1 |
− at V/2 = 80 m/us | 0.4 | 0.8 |
Uncertainty, % of range | 0.2 | 0.4 |
Input impedance, Ohm | 10 − 500 | 30 − 350 |
Pulse amplitude, V | 45 | 22 |
Pulse width, ns | 10 − 20000 | 10 − 19200 |
Dynamic range, dB | from -33 tо 104 | from -15 tо 98 |
Reflectograms for averaging count | 1 − 255 | |
Propagation velocity range (V/2), m/us | 50 − 150 | |
Propagation velocity (V/2) resolution, m/us | 0.1 | |
Max. input voltage, V | 50 | 20 |
Measuring methods: | ||
− TDR | yes | yes |
− ICE | yes | yes |
− Decay | yes | yes |
− ARC | yes | no |
Nonvolatile memory: | ||
− reflectograms with data | 1200 | 120 |
− propagation velocity data for cables | 1000 | 200 |
PC connectivity | USB, USB Flash, RS-485 | RS-232 (COM port) |
Firmware update via USB Flash | yes | no |
Display | color TFT resistive touch-screen 800 × 600 | b/w 320×240 |
Max. active time (when fully charged), hours | 8 | |
Power specifications: | ||
− power source (internal) | 12 AGM | 10АА×1.2V NiMh |
− power consumption, A | 1 | 0,5 |
− power source (external) | 12 − 24 | 12 − 18 |
− battery capacity, mA·h | 9000 | 2500 |
− charge current, mА | 1000 | 500 |
− leakage current when power OFF | 1 | 0.02 |
Dimensions, mm | 366×271×178 | 295×160×85 |
Net weight, kg | 8 | 2.3 |
rif-9-safenergy-i-din-moxa-ti-vit-nam