ANALYZER MEASURES AND RECORDS ACCORDING TO THE EN 61000 – 4-30 CLASS-A STANDARD
The device is designed to work with networks with nominal frequency 50/60 Hz.
The device is designed to work with networks with nominal voltage:
The network configuration is set from the computer software.
Supported networks:
ANALIZER MEASURES AND RECORDS ACCORDING TO THE EN 61000 – 4-30 CLASS-A STANDARD
The device is designed to work with networkswith nominal frequency 50/60 Hz.
The device is designed to work with networks with nominal voltage:
The network configuration is set from he computer software.
Supported networks:
Possible measurements:
Specification | Range | Resolution | Accuracy | |
AC voltage (TRMS) | – | 0,0…690,0 V | 0,01 % Un | ±0,1% Un |
Crest Factor | Voltage | 1,00…10,00 (≤1,65 for voltage 690 V) | 0,01 | ±5% |
Current | 1,00…10,00 (≤3,6 Inom) | 0,01 | ± 5% m.v. | |
AC current TRMS | – | depends on the clamp* | 0,01 % of nominal range | ±0,1% of nominal range (add clamps accuracy) |
Frequency | – | 40,00…70,00 Hz | 0,01 Hz | ±0,01 Hz |
Active, reactive, apparent power and distortion | – | depends of configuration (transformers, clamp) | up to 4 decimal places | depends on configuration (transformers, clamp) |
Active, reactive apparent energy | – | depends of configuration (transformers, clamp) | up to 4 decimal places | the same as above |
cosφ and Power Factor (PF) | – | 0,00…1,00 | 0,01 | ±0,03 |
tgφ | – | 0,00…10,00 | 0,01 | depends on Active and Reactive power accuracy |
Harmonics | Voltage | same as for AC voltage TRMS | same as for AC voltage TRMS | ±5% Uh for Uh ≥ 1% Un ±0,05% Un for Uh < 1% Un |
Current | same as for AC current TRMS | same as for AC current TRMS | ± 5% Ih for Ih ≥ 3% In ± 0,15% In for Ih < 3% In | |
Total Harmonics Distortion | Voltage | 0,0..100,0% | 0,1% | ±5% |
Current | ±5% | |||
Harmonics active and reactive power | – | depends on configuration (transformers, clamp) | depends on current and voltage minimum value | – |
Angle between voltage and current harmonics | – | -180,0…+180,0o | 0,1o | ±(h x 1o) |
K-Factor | – | 1,0…50,0 | 0,1 | ±10% |
Flicker | – | 0,20…10,00 | 0,01 | ±5% |
Unbalance | Voltage and Current | 0,0…20,0% | 0,1% | ±0,15% (absolute error) |
*Clamp F-1/F-2/F-3:0..3000 A (10000 Ap-p) *Clamp C-4: 0..1000 A (3600 Ap-p)*Clamp C-5: 0..1000 A (3600 Ap-p)*Clamp C-6: 0..10 A (36 Ap-p) (without current transformers)
Sonel Analysis 1.0
„SONEL Analysis” software is an application used to work with PQM-701 power quality analyzer. It enables:
Analyzer configuration
The software enables configuration of all analyzer’s parameters. The configuraton is made on the PC computer and later transfered to the analyzer. The configuration settings can be stored on hard drive or other data storage devices to be used later.The software enables the configuration of:
The analyzer has four independent Measurement Points. Each Measurement Point can be set individually to perform four different types of registration without need to change analyzer’s configuration.
For each Measurement Point the following settings can be made:
Recent data reading
“SONEL Analysis” software enables reading of selected parameters and their graphic presentation in real time.These parameters are measured independently of the registration saved on the memory card. User can check:
Data analysis
With “SONEL Analysis” software user can read data stored on the memory card and analyze them. Data from the analyzer can be stored on hard drive and be used later. This feature enables data archiving.
The user can analyze the data from the device.There is a choice of: