LFG-200

Underground cable route locator

Untitled 1

LFG-200 & PT-14 Cable route tracing Set, can be used for locating as well as tracing underground metal communications, such as any cables with metal cores as well as metal pipes. In addition, it provides operator with a quick detection of short circuits on cables as well as with an identification of a cable in a bunch.

LFG-200 is a 200 W low frequency generator with ability to inject a signal of three frequencies via direct connection to an object or via internal transmission loop antenna, which is built-in a cover lid. Basic frequencies are 491; 982 and 8440 Hz. There are options of using a single-frequency or multi-frequency signals at the output.

The power of the low frequency generator LFG-200 output signal can be adjusted up to 200 W with 10 W steps. This signal can be transmitted constantly or broken into separate blocks of 50 % duty cycle with 1 s repetition rate.

A load matching is made automatically. Main parameters, such as output power, load impedance, selected frequency are shown on OLED display. If a load is higher than 1000 Ω LFG‑200 automatically switches into output voltage setting mode. The output overload protection will trip, when operating on short-circuit loops (lower than 0.5 Ω).

MAIN FEATURES:

  • High-contrast graphic OLED display
  • Multifrequency operation
  • Operating frequencies can be changed upon request
  • Internal transmission loop antenna
  • Automatic load impedance matching
  • Ability to work with energized 0.4kV cables (inductive connection)
  • Overload protection

Cable Fault Detector PT-14 designed for fast and accurate searching for power cables and other communications, identification of coating defects and the depth, followed by mapping.

 

  • Technical Specifications
    ParameterValue
    Operating frequencies, Hz491/982/8440 (other frequencies –

    upon request)

    Max. Frequencies count, operated simultaneously3
    Output power range, W0 – 200
    Output power regulating step, W10
    Frequency selectionmanual
    Operating modesContinuous / Pulse
    Loop impedance matching range, Ω0.5 – 1000
    Loop impedance matching modeAuto
    Measured parameters ranges:
    Output voltage, V RMS0 – 600
    Output current, A RMS0 – 20.0
    Phase angle, º0 – 90
    Pulse duty cycle, %50
    Pulse repetition frequency, Hz1.0
    Measurement error, %, of FS1
    Power supply: 
    Input voltage, V230 ± 10 %
    Input voltage frequency, Hz50
    Max. power consumption from mains, VA300
    Dimensions, mm482 × 133 × 345
    Net weight, kg, max8

     

    Traser PТ-14 specification:

    ParameterValue
    Operating frequencies, Hz491/982/8440
    Bandwidth:
    RADIO mode, kHz10 − 36
    ONLINE mode, Hz48 − 10 000
    Sensitivity, μV1
    Track depth measurment error, %, max5
    Dimensions, mm700 × 300 × 140
    Weight, kg, max2,4
  • Operating Conditions

    The device is designed for an indoors operation under the following conditions:

    ConditionValue
    Air temperature, °Сfrom -5 to +45
    Relative humidity, %, up to80 at +25° С
    Atmospheric pressure, kPa (mm hg)84,0 – 106,7 (630 – 800)
  • Package Contents
    ComponentQuantity
    LFG-2001
    Fuse 20 A2
    Fuse 2 A1
    Traser PT-14Optional
     
    Documentation
    User’s Manual1

 