| • Technology |
| Standards | IEEE 802.3af/at for Power-over-Ethernet IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3ab for 1000BaseT(X) |
| • Interface |
| RJ45 Ports | 10/100/1000BaseT(X) for PoE OUT and DATA IN |
| PoE Pinout | Default: V+, V+, V-, V- for pin 4, 5, 7, 8 (Midspan, MDI, Mode B) Custom DIP switch setting: V+, V+, V-, V- for pin 1, 2, 3, 6 (Endspan, MDI, Mode A) |
| • Power Requirements |
| Input Voltage | 24/48 VDC, redundant dual inputs |
| Operating Voltage | 22 to 57 VDC |
| Input Current | 2.71 A @ 24 VDC |
| Overload Current Protection | Present |
| Connection | 1 removable 4-contact terminal block |
| Reverse Polarity Protection | Present |
| Power Consumption | Max. 5.29 W full loading without PD’s consumption |
| Power Budget | Max. 60 W for 1 PD’s consumption |
| • Physical Characteristics |
| Housing | Metal |
| IP Rating | IP30 protection |
| Dimensions | 115 × 30.3 × 78.8 mm (4.53 x 1.19 x 3.10 in) |
| Weight | 245 g (0.54 lb) |
| Installation | DIN-rail mounting, wall mounting (with WK-30) |
| • Environmental Limits |
| Operating Temperature | Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Ambient Relative Humidity | 5 to 95% (non-condensing) |
| • Standards and Certifications |
| Safety | UL 508, EN 60950-1 (LVD) |
| EMC | EN 55032/24 |
| EMI | CISPR 32, FCC Part 15B Class A |
| EMS | IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 3 kV; Signal: 3 kV IEC 61000-4-6 CS: Signal: 10 V IEC 61000-4-8 |
| Shock | IEC 60068-2-27 |
| Freefall | IEC 60068-2-32 |
| Vibration | IEC 60068-2-6 |
| • MTBF (mean time between failures) |
| Time | 2,407,739 hrs |
| Standard | Telcordia (Bellcore), GB |