HVTS-HP

Insulators tester

79 631.big

The insulators testing device HVTS-HP is designed for testing the insulation of power cables and solid dielectric with the rectified voltage of up to 100 kV, as well as testing solid dielectrics with the sinusoidal voltage of up to 100 kV, 50 Hz.

The main difference between series devices Cable test and diagnosis system HVTS-HP devices from Portable Hi pot Tester HVTS-70/50 is the increased power output. There are two standard versions: 7.5 KVA and 17.5 KVA.

Technical Specifications
 
Parameter
HVTS-HP
70/55-7,5 (17,5)
HVTS-HP
70/100-7,5 (17,5)
HVTS-HP
100/100-7,5 (17,5)
HVTS-HP
140/100-7,5 (17,5)
Output test AC voltage range, kV
0.5 – 55
1 – 100
Output test DC voltage range, kV
0.5 – 70
1 – 100
1 – 140
Output test AC current, mA, max
130 (300)
75 (175)
Output test DC current, mA, max
90 (200)
30 (65)
40 (90)
55 (125)
Output AC voltage measuring range, kV
3 – 55
3 – 100
Output DC voltage measuring range, kV
3 – 70
3 – 100
3 – 140
Output AC current measuring range, mA
1 – 130
(1 – 300)
1 – 75 (1 – 175)
Output DC current measuring range, mA
1 – 90
(1 – 200)
1 – 30
(1 – 65)
1 – 40
(1 – 90)
1 – 55
(1 – 125)
Measuring accuracy
3 % (of full scale)
Supply voltage, V
220 ± 22
Frequency, Hz
50    1
In parentheses are the parameters for the performance of 17.5 kVA version.
 
Package Contents
 
Component
Quantity
HVTS-HP-100/100-7,5 control unit with voltage regulator VT-40 on the mobile trolley
1
TIOG-100 on the mobile trolley bundled with voltage divider, earthing and rectifier
1
Power cable on the drum (length 10 m, cross-section 4×4 mm2)
1
Grounding cable on the drum (length 10 m, cross-section 10 mm2)
2
High voltage cable on the drum (length 10 m, U test = 70 kV)
1
Documentation
User’s Manual
1
 

backtotop